207
FR
ES
PT
IT
EL
PL
RU
KZ
UA
RO
EN
Problems Probable causes Solutions Qualification
Motor stops
Fuse faulty / blown Replace fuse Customer
Wrong mains voltage
Check that mains
voltage corresponds to
the specifications
Customer
Motor protector has
activated
Wait to cool for 15min
and try again
Customer
The plug has been
disconnected
Reconnect the plug Customer
The motor is out of
service
Contact the after sales
service
After Sales
Motor starts but
no pressure
Nozzle partly blocked Clean it Customer
Low pressure nozzle
selected
Change the nozzle
selection
Customer
Water inlet pressure is
too low
Check the inlet
pressure specification
Customer
The pump is blocked
Contact the after sales
service
After Sales
Water filter blocked Clean it Customer
The pump sealing is
damaged
Contact the after sales
service
After Sales
Pressure pulsating
Air in the inlet water
supply hose (espacially
by self priming funciton)
Remove the air from
the hose
Customer
Low pressure nozzle
selected
Change the nozzle
selection
Customer
Water filter blocked Clean it Customer
Water hose squeezed
Straighten out kinked
water supply hoses
Customer