6. System Confirm
This final test must be performed after repairing the unit. If all steps below are working
correctly the unit can be returned to the end user.
1. If available, set the unit in test station and turn the knob to the MIN position.
2. Connect electricity wiring to the unit and connect the water valve, then supply water to the
system to check for leaks but keep the main breaker to the unit turned off.
3. Check leak point by visual. If have some leak, please change O-Ring or gasket. ***
If Power Lamp on mean Triac Damage. Must change new one***
4. Continuous supply electricity and turn knob control on.
5. Turn right knob control to select temperature that you desire.
6. Check temperature by warmed water ready for use.
7. The confirmation process by checking on the approximate temperature of the water.
8. Finalize, Purge water in tank by air blow until dry.
***Remark: Change inlet for the whole set see in spare parts list.
Visual check