EasyManua.ls Logo

STIEBEL ELTRON CK 150-1 Plus - Mounting the Heater Unit; Electrical Connection and Wiring

STIEBEL ELTRON CK 150-1 Plus
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION
Installation
www.stiebel-eltron-usa.com CK Plus & CK Premium | 11
ENGLISH
Note
- The wall mounting bracket can be used as a tem-
plate for wall mounting. This ensures sufficient
clearance from the floor.
- Use a level if the floor is uneven or sloping.
aaa
D0000072159
1
3
2
4
≥7¼˝≥7¼˝
(≥18.3 cm) (≥18.3 cm)
D0000074798
f Unhook the wall mounting bracket from the heater.
f Place the centered wall mounting bracket horizontally on the
floor. Mark holes1 and 2.
f Lift up the wall mounting bracket so that its lower holes line
up with the markings you have just made on the installation
wall.
f Mark holes3 and 4 on the installation wall.
f Drill the holes at the 4markings.
f Secure the wall mounting bracket with suitable fixing mate-
rials (screws, wall anchors). With the vertical slots, you can
compensate for an offset mounting hole.
12.3 Heater installation
D0000074794
Wall
mounting
bracket
f Hook the heater onto the bottom tabs of the wall mounting
bracket using the slots in the back of the heater.
f Place the heater in an upright position.
f Secure the heater by pushing it towards the wall until it au-
dibly snaps into place with the two upper springs on the wall
mounting bracket.
D0000074795
2
1
1 Heater
2 Captive locking screws (attached)
f Secure the heater against unintentional release, using the
supplied captive locking screws on the left- and right-hand
sides of the wall mounting bracket.
12.4 Dismounting the heater
f Loosen the captive locking screws attached to the wall
mounting bracket.
f To release the heater, push down the springs at the top of the
wall mounting bracket.
f Tilt the heater away from the wall and lift it off the bottom
tabs of the wall mounting bracket.
12.5 Electrical connection
WARNING Electrocution
- Carry out all electrical connection and installation
work in accordance with relevant regulations.
- The heater must be able to be separated from the
power supply by an isolator that disconnects all
poles with at least 1/8˝ (3mm) contact separation.
Material losses
- Observe the type plate. The specified voltage must
match the supply line voltage.
- Ensure the on-site power supply cable is of an ade-
quate gauge to meet all applicable codes.
Never install the heater directly below a wall outlet.
CK 150-1 (120 V) models are supplied fully wired with a standard
120 V AC grounded cable with plug. For an optional permanent
connection, CK 150-1 models may also be hard-wired to a properly
sized circuit breaker.
CK 200-2 (208–240 V) models must be connected to a properly
sized circuit breaker. See section 16.2, “Data table”, pg. 13, and
section 16.3, “Wiring diagrams, pg. 13.

Table of Contents

Related product manuals