OPERATION AND INSTALLATION
OPERACIÓN E INSTALACN
UTILISATION ET INSTALLATION
Tankless Electric Water Heater
Calentador de Agua Instantaneos sin Tanque
Chauffe-Eau Électrique sans Accumulateur
» DHC 3-1
» DHC 3-2
» DHC 4-2
» DHC 4-3
» DHC 5-2
» DHC 6-2
» DHC 8-2
» DHC 9-3
» DHC 10-2
Conforms to ANSI/UL Std. 499
Certified to CAN/CSA Std. E335-1 & E335-2-35
Conforme a ANSI/UL Std. 499
Certicación con CAN/CSA Std. E335-1 & E335-2-35
Conforme à la norme ANSI/UL Std. 499
Certifié à la norme CAN/CSA Std. E335-1 & E335-2-35
Tested and certified by WQA to NSF/ANSI372
for lead free compliance.
Probado y certificado por WQA NSF/ANSI 372 para
el cumplimiento de las regulaciones sin plomo.
Testé et certifié par WQA à la NSF/ANSI 372 pour une
utilisation sans plomb.

Table of Contents

Other manuals for STIEBEL ELTRON DHC 10-2

Questions and Answers

  • D
    David SteeleAug 6, 2025
    Why is my STIEBEL ELTRON Water Heater clicking but not heating?
    • W
      wintersnicoleAug 6, 2025
      If your STIEBEL ELTRON Water Heater isn't providing hot water, but you hear a clicking sound, the problem could be a tripped circuit breaker. Try turning the circuit breaker on. Alternatively, the safety thermal cut-out may have tripped; in this case, reset the thermal cut-out.
  • V
    Vickie SchmidtAug 11, 2025
    How to fix a STIEBEL ELTRON DHC 10-2 Water Heater that is not warm enough?
    • J
      Justin JosephAug 11, 2025
      If the water from your STIEBEL ELTRON Water Heater isn't warm enough, it could be due to a high water flow. Try reducing the water flow and closing the flow adjustment screw. It could also be that the voltage is too low, so ensure the unit is receiving the correct voltage.
  • L
    lhardyAug 16, 2025
    What to do if my STIEBEL ELTRON DHC 10-2 Water Heater has no hot water and no click?
    • W
      Wendy JohnsonAug 16, 2025
      If your STIEBEL ELTRON Water Heater isn't producing hot water and you don't hear a click when turning the water on, it's likely due to insufficient water flow activating the flow switch. Here are a few things you can try: * Clean the faucet aerator. * Completely open the shut-off valve. * Open the flow adjustment screw. * Clean the filter screen at the DHC unit.
  • J
    Jean WallaceAug 21, 2025
    Why is my STIEBEL ELTRON Water Heater water not warm enough?
    • D
      daniel21Aug 22, 2025
      If the water from your STIEBEL ELTRON Water Heater isn't warm enough, it could be due to a couple of reasons. First, the water flow might be too high; try reducing the water flow by closing the flow adjustment screw. Alternatively, the voltage supplied to the unit might be too low, in which case you should ensure the correct voltage is supplied.
  • M
    Mrs. Julie ThompsonAug 26, 2025
    How to fix STIEBEL ELTRON DHC 10-2 with no hot water but audible click?
    • C
      Courtney GoodmanAug 26, 2025
      If your STIEBEL ELTRON Water Heater isn't producing hot water, but you hear a click when the water is turned on, the issue might stem from either a tripped circuit breaker, which you should turn on, or a tripped safety thermal cut-out, which you should reset.
  • B
    Brianna BarronAug 31, 2025
    What to do if my STIEBEL ELTRON DHC 10-2 has no hot water and no audible click?
    • M
      Monique AllenAug 31, 2025
      If your STIEBEL ELTRON Water Heater isn't producing hot water and you don't hear a click, the issue might be due to low water flow preventing the flow switch from activating. Try cleaning the faucet aerator. Also, ensure the shut-off valve is completely open. You may also need to open the flow adjustment screw or clean the filter screen at the DHC unit.

Summary

General Information

Safety Information

Provides critical safety information and warnings to ensure safe operation of the appliance.

Other Symbols in this Document

Explains various symbols used throughout the manual for clarity and understanding.

Safety

Intended Use

Specifies the intended domestic and commercial applications for the water heater.

General Information

Provides general operational guidelines and important warnings for safe use.

Safety Precautions

Details specific safety precautions, potential dangers, and required actions during installation and use.

Test Symbols

Refers to the appliance's type plate for relevant test symbols and certifications.

Register Your Product

General Product Overview

Mounting the Unit

Water Connections

Electrical Connection

Terminal Block

Specifies torque values for securing wires to the terminal block during electrical connection.

Commissioning

Appliance Handover

Instructions for explaining the appliance's functions and providing documentation to the user.

Troubleshooting

Normal Maintenance

Technical Data

Dimensions

Provides the physical dimensions of the water heater unit.

Wiring Diagram

Illustrates the electrical wiring connections for different models of the appliance.

Temperature Increase Above Ambient Water Temperature

Tables showing temperature rise based on flow rate and power for various models.

Data Table

A comprehensive table detailing electrical, hydraulic, and application specifications.