6
With the Room temp. parameter you can adjust the set
room temperature of the heating circuit for the day and
setback mode.
In the Heating curve parameter, you can adjust the
heating curve. The room temperature will only remain
constant, irrespective of the outside temperature, if the
correct heating curve has been selected for the relevant
type of building. Selecting the correct heating curve is
therefore vitally important.
In the Heating program parameter, you can adjust the
heating program.
The Temperatures parameter enables you to scan the
sensor temperatures of the heat pump or heat pump
system, comparing the actual with the set temperatures,
the relative humidity, etc.
.
During
commissioning, you need to not only determine
the settings of control level 2, but also the system-specific
parameters. These parameters are adjusted at control
level 3 by your heating contractor, access to which is
protected by code.
1.5.5 Overview of system parameter (control level 2)
Select the required parameter with the rotary selector.
For adjustments to parameters, turn to page 6.
ROOM T
HTG PROG
TEMPERATURES
HTG CURVE
CONTRACTOR