16 
 
10

1

The more coarsely porous, blue
side is the air intake side of the
filter.
The direction of flow is indicated by an
arrow on the side of the filter.
Replace the filter.
Push the new filter cassette into the appliance.
Rotate the filter cover back into its original position and then
tighten the r.h. knurled nut clockwise.
Tighten the l.h. knurled nut.
At the programming unit, activate the „RESET FILTER“ para-
meter („SETTINGS/ VENTILATION/ SERVICE).
WARNING Injury
All other work on the appliance must only be carried out
by qualified contractors.
Note
Have the cross-countercurrent heat exchanger, outdoor
air filter, evaporator and fans checked and (if required)
cleaned once a year by a qualified contractor.
5.2 Replacing the outdoor air filter
The outdoor air filter is fitted downstream of the cross-counter-
current heat exchanger. The outdoor air filter must be replaced
by a qualified contractor.
5.3 Cleaning the extract and supply air vent filters
If installed, clean the extract air vent filters through which air
is extracted from the rooms.
If installed, clean the supply air vent filters through which air
is supplied to the rooms.
Clean the filter box (if present) attached to the outdoor air
connector on the rear of the appliance.
6. Troubleshooting
6.1 Filter symbols appear
The appliance is equipped with an automatic filter contamination
detector. The constant flow rate control of the fans results in an
increase in fan speed when the filters become contaminated. This
increase in speed is evaluated to display a filter change require-
ment.
When the filters are contaminated, the following symbols are di-
splayed.
Filter change, top:
The extract air filter is contaminated. Please change the
extract air filter.
Filter change, bottom:
The supply air filter is contaminated. Please change the
supply air filter.
Filter change, top and bottom:
Extract air and supply air filters are contaminated or their
filter change intervals have expired. Please change the
extract air and supply air filters.
The filter symbol appears automatically after three months.
6.2 No hot water
Should you fail to obtain hot water, you can take the following
steps to remedy the situation yourself:
- If the appliance has no power: Check the fuse/circuit breaker
in your fuse box. If it has blown/tripped, replace/reset the
fuse/MCB. Notify your qualified contractor if the fuse/MCB
blows/trips again.
- If the appliance has power: Check whether the air intake/
discharge is blocked. Check whether a fault code is being
displayed, and if necessary, notify your qualified contractor.
Check whether the control unit is set correctly.
6.3 The safety valve of the cold water supply line
is dripping
This may occur during the heat-up phase and is completely nor-
mal.
6.4 The fault symbol appears
Note
If this symbol appears, it means a fault has occurred.
Notify your qualified contractor or call customer service.
6.5 The appliance leaks water
If water escapes from the appliance, shut it down immediately and
notify your qualified contractor.
6.6 Condensate on the outside of the appliance or
on the air hoses
In the drying out phase or when relative humidity is high (>60%),
it is normal for condensate to appear on the surface of the appli-
ance and on the thermally insulated air hoses. This should stop
when the house has dried out thoroughly which, subject to the
design, can take up to 2 years. If the room is used to dry washing
however, condensate can still form.
Check whether the air hoses are fitted correctly, and that no
cold air escapes.
6.7 Noise is emitted
Since the appliance moves very large volumes of air, it cannot
work silently.
However, there should not be any disturbing noises in the living
rooms and bedrooms. To achieve this, ensure that
- the appliance has been installed correctly.
- the installation room has a door that closes tightly.
- adequately sized silencers are integrated directly on the ap-
pliance in the supply air and extract air ducts.
- additional silencers are installed between bedrooms, nurse-
ries and living rooms.

Other manuals for STIEBEL ELTRON LWZ 8 CS Premium

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STIEBEL ELTRON LWZ 8 CS Premium and is the answer not in the manual?

STIEBEL ELTRON LWZ 8 CS Premium Specifications

General IconGeneral
BrandSTIEBEL ELTRON
ModelLWZ 8 CS Premium
CategoryHousehold Appliance
LanguageEnglish

Related product manuals