w LWZ 5-8 CS Premium / 19
COLLECTOR TEMP. °C Temperature of the solar collector
HEAT GENERATOR
HEATING STAGE
HEAT PUMP
HOT GAS TEMPERATURE °C This value specifies the temperature of the gaseous refrigerant at the condenser inlet.
HIGH PRESSURE bar
LOW PRESSURE bar
EVAPORATOR TEMP. °C In the evaporator, the refrigerant is evaporated at low pressure. As this happens, heat is extracted from
the air flow.
CONDENSER TEMP. °C In the condenser, the refrigerant is liquefied at high pressure. This releases heat which is transferred to
the heating medium.
OIL SUMP TEMPERATURE °C
EXHAUST AIR ACTUAL Hz Current speed of the exhaust air fan
EXHAUST AIR SET Set flow rate of the heat pump fan
DIFF. PRESSURE EVAP. Pa
COMPRESSOR STARTS
AMOUNT OF HEAT
HEAT METER HTG DAY kWh Amount of heat that was transferred by the heat pump to the heating circuit on this day.
HEAT METER HTG TTL MWh Amount of heat that has been transferred by the heat pump to the heating circuit since the appliance
was commissioned.
HEAT METER DHW DAY kWh Amount of heat that was transferred by the heat pump to the DHW cylinder on this day.
HEAT METER DHW TTL MWh Amount of heat that has been transferred by the heat pump to the DHW cylinder since the appliance was
commissioned.
HEAT M BOOST HTG TTL MWh Amount of heat that has been transferred by the electric emergency/booster heater to the heating circuit
since the appliance was commissioned
HEAT M BOOST DHW TTL MWh Amount of heat that has been transferred by the electric emergency/booster heater to the DHW cylinder
since the appliance was commissioned
HEAT M RECOVERY DAY kWh Amount of heat that was recovered from the ventilation system on this day.
HEAT M RECOVERY TTL MWh Amount of heat that has been recovered from the ventilation system since the appliance was commis-
sioned.
HM SOLAR HTG DAY kWh Amount of heat that was transferred by the solar thermal system to the heating circuit on this day.
HM SOLAR HTG TOTAL MWh Amount of heat that has been transferred by the solar thermal system to the heating circuit since the
appliance was commissioned.
HM SOLAR DHW DAY kWh Amount of heat that was transferred by the solar thermal system to the DHW cylinder on this day.
HM SOLAR DHW TOTAL MWh Amount of heat that has been transferred by the solar thermal system to the DHW cylinder since the
appliance was commissioned.
HM COOLING TOTAL MWh Amount of heat absorbed by the appliance via its evaporator from the rooms.
RUNTIMES Here, the runtime of some appliance components since appliance commissioning is shown.
COMPRESSOR HEATING h
COMPRESSOR COOLING h
COMPRESSOR DHW h
ELEC BOOSTER HEATING h
ELEC BOOSTER DHW h
POWER CONSUMPTION
PWR CON HTG DAY kWh Power drawn by the compressor on this day for supplying the heating circuit.
PWR CON HTG TTL MWh Power drawn by the compressor since commissioning for supplying the heating circuit
PWR CON DHW DAY kWh Power drawn by the compressor on this day for supplying the DHW cylinder
PWR CON DHW TTL MWh Power drawn by the compressor since commissioning for supplying the DHW cylinder
DIAGNOSIS
SYSTEM STATUS
POWER-OFF
STOVE / FIREPLACE
AIR HEAT EXCH. DEFR.
EVAPORATOR DEFROST
SILENTMODE Status of sound-reduced night mode ( 1 = activ e, 0 = inactive )
SOLAR Status of the solar circuit pump ( 1 = activ e, 0 = inactive )
SUMMER MODE Here, the display shows whether the appliance is in summer mode (1 = summer mode).
FAULT LIST