10. Installation
10.1 Standard installation
- Electrical connection from above; installation on unfinished
walls
- Water connection on unfinished walls
For further installation options, see chapter "Alternative instal-
lation methods":
- Electrical connection from below on unfinished walls
- Electrical connection on finished walls
- Connecting a load shedding relay
- Water installation on finished walls
- Water connection on unfinished walls for appliance
replacement
Opening the appliance
D0000041615
Open the appliance by releasing the snap lock.
NT
T-
so
X1
26�02�02�0762
Remove the back panel by pressing the two locking tabs and
pulling the lower section of the back panel forwards.
Preparing the power cable
160
≥ 30
26�02�02�0887
Fitting the wall mounting bracket
26�02�02�0972
Mark out the holes for drilling using the installation tem-
plate. If the appliance is to be installed with water connec-
tions on finished walls, also mark out the fixing holes in the
lower part of the template.
Drill the holes and secure the wall mounting bracket with
2screws and 2rawl plugs (screws and rawl plugs are not
part of the standard delivery).
Fit the threaded stud provided.
Fit the wall mounting bracket.
Fitting the cable grommet
26�02�02�0950
Fit the cable grommet. For connecting cables >6mm², en-
large the hole in the cable grommet.