26 | SH S www.stiebel-eltron.com
INSTALLATION
Settings
12. Settings
Limiting the temperature selection
You can adjust the temperature selection limit beneath the tem-
perature selector.
Set the temperature selector to "cold" and isolate the appli-
ance from the power supply.
Remove the temperature selector.
1
2
3
26�02�07�0099
1 Temperature selector
2 Temperature selection limit at 45°C, 55°C, 65°C
3 Factory setting 85°C
Adjust the temperature selection limit.
Replace the temperature selector.
13. Shutting down
Disconnect the appliance from the mains at the MCB/fuse in
the fuse box.
Drain the appliance (see chapter "Maintenance/ Draining the
appliance").
14. Troubleshooting
Note
At temperatures below –15°C the high limit safety cut-out
may respond. The appliance may be subjected to these
temperatures during storage or transport.
Fault Cause Remedy
The water does not heat
up.
The high limit safety
cut-out has responded
because the controller is
faulty.
Remedy the cause of
the fault. Replace the
controller-limiter com-
bination.
The high limit safety
cut-out has responded
because the temperature
has fallen below -15°C.
Press the reset button
(see diagram).
The flanged immersion
heater is faulty.
Replace the flanged im-
mersion heater.
The safety valve drips
when heating is switched
off.
The valve seat is contam-
inated.
Clean the valve seat.
SERVICE ANODE indicator
illuminates.
The signal anode has
been consumed.
Replace the signal anode.
Reset key, high limit safety cut-out
The reset button is located behind the temperature selector.
Pull off the temperature selector.
12
D0000038570
1 Reset key, high limit safety cut-out
2 Controller/limiter combination