INSTALLATION
Installation
www.stiebel-eltron.com SHP-A 220-300 Plus | 19
ENGLISH
WARNING Electrocution
Coming into contact with 'live' components presents a
threat to life. Disconnect the appliance from the power
supply before carrying out work on the control panel.
Prevent the power supply from being switched on while
you are working on the system.
WARNING Electrocution
Insufficient earthing can lead to electrocution. Ensure
the appliance is earthed according to locally applicable
requirements.
WARNING Electrocution
The power cable must only be replaced (for example
if damaged) with an original spare part by a qualified
contractor authorised by the manufacturer (connection
typeX).
!
Material losses
Install a residual current device (RCD).
!
Material losses
The specified voltage must match the mains voltage. Ob-
serve the type plate.
!
Material losses
Never connect the appliance to the power supply before
the DHW cylinder is filled.
The appliance is delivered with a power cable with fitted plug.
10.4.1 Standard connection without external signal transmitter
X0
2
L
L
N
N
PE
PE
GNYE
BU
BN
1
1
2
X3
2
3
3
1
1
2
D0000059150
BN Brown
BU Blue
GNYE Green/yellow
10.4.2 Connection options: Operation with external switching
device that interrupts appliance power supply
To ensure cylinder corrosion protection, appliances are equipped
with a maintenance-free impressed current anode as standard. A
maintenance-free impressed current anode, when compared to a
sacrificial anode, offers the greatest protection and saves on costs
for maintenance that would otherwise be required. To ensure cyl-
inder corrosion protection however, the impressed current anode
must be supplied with power permanently.
If the device is to be used with external switching devices (e.g.
external time switch, switched socket, energy management sys-
tem, power-interrupting signal from the power supply utility)
that interrupt the appliance power supply, the impressed current
anode must not be subject to the effects of such devices, but sup-
plied independently. For such cases, the appliance allows separate
power supplies for load (compressor) and electronic (including
impressed current anode) circuits.
Remove the appliance cover (see chapter “Cleaning and
maintenance/ Removing the appliance cover”).
D0000056083
1
2
1 Strain relief
2 Terminal X0
Prepare the electric cables in such a way that each cable ter-
minates with a wire ferrule.
Push the cables through one of the cable entries in the appli-
ance casing.
Route leads through the strain relief.
Remove the jumper which leads from X0/N to X0/2 in the de-
livered condition.
Remove the jumper which leads from X0/L to X0/1 in the de-
livered condition.
X0
2
L
L
N
N
PE
PE
L
N
PE
GNYE
BU
BN
1
1
2
X3
2
3
3
1
1
2
L1 / L2 / L3
N
A
B
D0000059152
A Power supply provided by power supply utility or energy
management system for switching the load (compressor)
B Power supply to impressed current anode and PCB
BN Brown
BU Blue
GNYE Green/yellow
Connect the electric cables for the separate impressed cur-
rent anode power supply to X0/1 and X0/2.
!
Material losses
The power supply to the impressed current anode must
be continuously ensured.
!
Material losses
With regard to the external switching device, the min-
imum runtime and minimum pause times must be ob-
served (see chapter "Appliance description/Minimum