Table showing temperature increase above ambient water temperature1
Maximum temperature increase above ambient water temperature
English
Warm water flow rate
GPM l/min
Warm water outlet temperature
140 °F 60 °C
TEMPRA 12 / TEMPRA 12 Plus @ 208 V 9 kW 0.61 0.76 0.97 1.36 2.27 6.61 2.30 2.86 3.68 5.16 8.59 25.00
@ 220 - 240 V 12 kW 0.81 1.01 1.30 1.82 3.03 6.61 3.07 3.82 4.91 6.87 11.46 25.00
TEMPRA 15 / TEMPRA 15 Plus @ 208 V 10,8 kW 0.73 0.91 1.17 1.63 2.72 6.61 2.76 3.44 4.42 6.19 10.31 25.00
@ 220 - 240 V 14.4 kW 0.97 1.21 1.56 2.18 3.63 6.61 3.68 4.58 5.89 8.25 13.75 25.00
TEMPRA 20 / TEMPRA 20 Plus @ 208 V 14.4 kW 0.97 1.21 1.56 2.18 3.63 6.61 3.68 4.58 5.89 8.25 13.75 25.00
@ 220 - 240 V 19.2 kW 1.30 1.61 2.08 2.91 4.84 6.61 4.91 6.11 7.86 11.00 18.33 25.00
TEMPRA 24 / TEMPRA 24 Plus @ 208 V 18 kW 1.22 1.51 1.95 2.72 4.54 6.61 4.60 5.73 7.36 10.31 17.18 25.00
@ 220 - 240 V 24 kW 1.62 2.02 2.59 3.63 6.05 6.61 6.14 7.64 9.82 13.75 22.91 25.00
TEMPRA 29 Plus @ 208 V 21.6 kW 1.46 1.82 2.33 3.27 5.45 6.61 5.52 6.87 8.84 12.37 20.62 25.00
@ 220 - 240 V 28.8 kW 1.95 2.42 3.11 4.36 6.61 6.61 7.36 9.16 11.78 16.50 25.00 25.00
TEMPRA 36 Plus @ 208 V 27 kW 1.82 2.27 2.92 4.09 6.61 6.61 6.90 8.59 11.05 15.47 25.00 25.00
@ 220 - 240 V 36 kW 2.43 3.03 3.89 5.45 6.61 6.61 9.21 11.46 14.73 20.62 25.00 25.00
Cold water inlet temperature °F °C
39 59 77 95 113 131 4 15 25 35 45 55
Warm water outlet temperature
113 °F 45 °C
TEMPRA 12 / TEMPRA 12 Plus @ 208 V 9 kW 0,83 1,14 1,70 3,41 6,61 3,14 4,30 6,44 12,89 25,00
@ 220 - 240 V 12 kW 1,11 1,51 2,27 4,54 6,61 4,19 5,73 8,59 17,18 25,00
TEMPRA 15 / TEMPRA 15 Plus @ 208 V 10,8 kW 1,00 1,36 2,04 4,09 6,61 3,77 5,16 7,73 15,47 25,00
@ 220 - 240 V 14.4 kW 1,33 1,82 2,72 5,45 6,61 5,03 6,87 10,31 20,62 25,00
TEMPRA 20 / TEMPRA 20 Plus @ 208 V 14.4 kW 1,33 1,82 2,72 5,45 6,61 5,03 6,87 10,31 20,62 25,00
@ 220 - 240 V 19.2 kW 1,77 2,42 3,63 6,61 6,61 6,71 9,16 13,75 25,00 25,00
TEMPRA 24 / TEMPRA 24 Plus @ 208 V 18 kW 1,66 2,27 3,41 6,61 6,61 6,29 8,59 12,89 25,00 25,00
@ 220 - 240 V 24 kW 2,21 3,03 4,54 6,61 6,61 8,38 11,46 17,18 25,00 25,00
TEMPRA 29 Plus @ 208 V 21.6 kW 1,99 2,72 4,09 6,61 6,61 7,54 10,31 15,47 25,00 25,00
@ 220 - 240 V 28.8 kW 2,66 3,63 5,45 6,61 6,61 10,06 13,75 20,62 25,00 25,00
TEMPRA 36 Plus @ 208 V 27 kW 2,49 3,41 5,11 6,61 6,61 9,43 12,89 19,33 25,00 25,00
@ 220 - 240 V 36 kW 3,32 4,54 6,61 6,61 6,61 12,57 17,18 25,00 25,00 25,00
Cold water inlet temperature °F °C
39 59 77 95 113 131 4 15 25 35 45 55
Warm water outlet temperature
105 °F 40 °C
TEMPRA 12 / TEMPRA 12 Plus @ 208 V 9 kW 0,95 1,36 2,27 6,61 3,58 5,16 8,59 25,00
@ 220 - 240 V 12 kW 1,26 1,82 3,03 6,61 4,77 6,87 11,46 25,00
TEMPRA 15 / TEMPRA 15 Plus @ 208 V 10,8 kW 1,14 1,63 2,72 6,61 4,30 6,19 10,31 25,00
@ 220 - 240 V 14.4 kW 1,51 2,18 3,63 6,61 5,73 8,25 13,75 25,00
TEMPRA 20 / TEMPRA 20 Plus @ 208 V 14.4 kW 1,51 2,18 3,63 6,61 5,73 8,25 13,75 25,00
@ 220 - 240 V 19.2 kW 2,02 2,91 4,84 6,61 7,64 11,00 18,33 25,00
TEMPRA 24 / TEMPRA 24 Plus @ 208 V 18 kW 1,89 2,72 4,54 6,61 7,16 10,31 17,18 25,00
@ 220 - 240 V 24 kW 2,52 3,63 6,05 6,61 9,55 13,75 22,91 25,00
TEMPRA 29 Plus @ 208 V 21.6 kW 2,27 3,27 5,45 6,61 8,59 12,37 20,62 25,00
@ 220 - 240 V 28.8 kW 3,03 4,36 6,61 6,61 11,46 16,50 25,00 25,00
TEMPRA 36 Plus @ 208 V 27 kW 2,84 4,09 6,61 6,61 10,74 15,47 25,00 25,00
@ 220 - 240 V 36 kW 3,78 5,45 6,61 6,61 14,32 20,62 25,00 25,00
Cold water inlet temperature °F °C
39 59 77 95 113 131 4 15 25 35 45 55