INSTALLATION
Preparations
www.stiebel-eltron.com WPL 10 AC | WPL 10 ACS | 9
Example: Wall mounting bracket WK 1
≥200
2
5
3 1
4
D0000019244
1 Heating flow
2 Heating return
3 Condensate drain
4 Drainage pipe
5 Wall mounting bracket
Observe the static limits of the building wall and the wall
mounting bracket.
Example: Mounting bracket MK 1
610
635
265
525
1350
e01
e02
80
110
b01
120
4
5
1
3
2
D0000034844
b01 Entry electrical cables
e01 Heating flow
e02 Heating return
1 Air intake side
2 Air discharge side
3 Main wind direction
4 Condensate drain
5 Supply line outlet
2
8
7
3
4
6
1
2
1
9
5
A
70-80
D0000024451
A Depth of frost line
1 Heating flow
2 Heating return
3 Conduit for supply lines/cables
4 Foundation
5 Mounting bracket
6 Gravel bed
7 Drainage pipe
8 Condensate drain
9 Outlet for supply lines opt.
9.6 WPM 3 heat pump manager
A WPM3 heat pump manager is required to operate the appliance.
This controls the entire heating system.
9.7 Buffer cylinder
A buffer cylinder is recommended to ensure trouble-free appliance
operation.
The buffer cylinder provides hydraulic separation of the volume
flows in the heat pump circuit and heating circuit, and also serves
as an energy source for defrosting.
When operating without buffer cylinder, observe the details
specified in chapter "Minimum flow rate with individual room
controller by means of FEK / FE7 in the case of systems with-
out buffer cylinder".
!
Material losses
A buffer cylinder with diffusion-proof insulation is essen-
tial for cooling mode.