INSTALLATION
Electrical connection
18 | WPL-A Premium www.stiebel-eltron.com
11. Electrical connection
Note
The leakage current of this appliance can be >3.5mA.
Note
f Please observe the instructions for the heat pump
manager.
The connection must only be made by a qualified contractor and
in accordance with these instructions.
You must have permission to connect the appliance from the rel-
evant power supply utility.
11.1 Terminal area
WARNING Electrocution
f Before working on the appliance, isolate it from the
power supply at the control panel.
Note
The terminals are located in the terminal area of the ap-
pliance.
f Follow the instructions in the chapter "Preparation/ Prepar-
ing the electrical installation".
f For all connections, use appropriate cables in accordance
with local regulations.
Access to the terminal area
D0000035356
D0000035358
f Push the cover upwards.
D0000090349
1
2
1 Terminal area
2 Strain relief
f Route cables and leads through the strain relief fittings.
If space behind the appliance is limited, the terminal area can be
folded out.
D0000090351
f Undo the screw on the terminal area.