INSTALLATION
Preparation
www.stiebel-eltron.com WPL-A Premium | 9
9.3 Minimum clearances
Note
f If the appliance is installed close to light wells, it is
essential that you observed the safety clearances to
those light wells (see chapter "Safety clearances as
required by the safety concept").
≥2000
≥500
≥300
≥1000
≥800
D0000028299
f Maintain the minimum clearances to ensure trouble-free op-
eration of the appliance and facilitate maintenance work.
D0000096921
f Never install the appliance in a recess. Two sides of the ap-
pliance must remain exposed.
!
Material losses
Please note that both the flow of outdoor air into the
appliance, and the flow of exhaust air from the appliance
must be unimpeded.
If the air intake and discharge of the appliance are ob-
structed by surrounding objects, this may cause a thermal
short circuit.
9.3.1 Minimum clearances with cascades
≥500
≥500
≥1000
D0000078118
≥300
≥300
D0000078119
≥300
≥300
≥250≥250
1
2
2
D0000078120
3
1 Main wind direction
2 Air discharge
3 Wall or wind protection