16 | WWK222-302 H www.stiebel-eltron.com
INSTALLATION
Installation
X0
2
L
L
N
N
PE
PE
L
N
PE
GNYE
BU
BK
1
1
2
X3
2
3
3
1
1
2
L1 / L2 / L3
N
A
B
D0000055663
A Power supply provided by power supply utility or energy
management system for switching the load (compressor)
B Power supply for the impressed current anode and the
electronics
BK black
BU blue
GNYE green/yellow
Connect the electric cables for the separate impressed cur-
rent anode power supply to X0/1 and X0/2.
10.3.3 Connection with external signal transmitter
Note
This type of connection must only be carried out by a
qualified electrician.
Note
The appliance has a second and higher set temperature
preselected at the factory. This is activated in the event
of an external switching signal. Set temperature2 takes
priority over the standard set temperature while there is
an external switching signal.
An external signal transmitter for switching a separate set DHW
temperature (set temperature2) can be connected to terminal
X3/1-2. In the delivered condition, terminal X3/1-2 is not assigned.
If this terminal is connected at the voltage stated in the specifica-
tion (see "Permissible voltage range, external signal transducer")
(L to X3/1, N to X3/2), the appliance activates set temperature2.
Following a one-off activation (signal is present for at least 1min-
ute), set temperature2 applies for at least 20minutes. Set temper-
ature2 is ranked higher than set temperature1. When the relevant
set DHW temperature has been reached, the compressor switches
off and remains off for a minimum idle time of 20minutes.
The following diagram illustrates the connections by means of a
sample signal sequence of an external signal transmitter.
Example:
- Water temperature = 61°C
- Set temperature 1 = 60°C
- Set temperature 2 = 65°C
D0000034613
A External signal
B Compressor
1 20 min. minimum runtime, set temperature2
2 20 min. minimum compressor idle time
Remove the appliance cover (see chapter "Cleaning and
maintenance/ Removing the appliance cover").
D0000056083
1
2
1 Strain relief
2 Terminal X3
Prepare the electric cables in such a way that each cable ter-
minates with a wire ferrule.
Push the cables through one of the cable entries in the appli-
ance casing.