17 Troubleshooting
17.1 Troubleshooting Cultivator
Most malfunctions have the same causes.
Perform the following operations:
Clean the air filter.
Clean or replace the spark plug.
Carry out the standard setting.
Adjust idle speed.
Adjust carburetor for operation at high altitude.
If the malfunction still exists: Take the action described in the following table.
Condition Cause Remedy
Engine does not
start.
Insufficient fuel in the
tank.
Mix fuel and refuel the cultivator.
Engine is flooded. Clear the combustion chamber.
Carburetor is too hot. Allow cultivator to cool down.
Before starting the engine: Depress the manual fuel
pump bulb at least ten times.
Carburetor is iced up. Allow cultivator to warm up to +10°C.
Engine idles errati‐
cally.
Carburetor is iced up. Allow cultivator to warm up to +10°C.
Engine stops while
idling
Carburetor is iced up. Allow cultivator to warm up to +10°C.
17.2 Standard Setting
Shut off the engine.
0000-GXX-2946-A0
H
L
Turn the high speed screw (H) counterclock‐
wise as far as stop.
Turn the low speed screw (L) clockwise as far
as stop.
Turn the low speed screw (L) 3/4 of a turn
counterclockwise.
17.3 Adjusting Idle Speed
Carry out the standard setting.
Start the engine.
Warm up the engine by opening and closing
the throttle for about 1 minute.
0000-GXX-4782-A0
Engine stops while idling
Turn the idle speed screw (LA) clockwise until
the blades begin to rotate.
Turn the idle speed screw (LA) one full turn
counterclockwise.
Erratic idling behavior or poor acceleration
Turn the low speed screw (L) clockwise or
counterclockwise until the engine runs and
accelerates smoothly.
Blades rotate when engine is idling
Turn the idle speed screw (LA) counterclock‐
wise until the blades stop rotating.
Turn the idle speed screw (LA) one full turn
counterclockwise.
English 17 Troubleshooting