0458-724-8601-A
15
English
11 Adjusting the Blower
► Secure the cable grommet (11) in the cable clamp (12).
10.2 Mounting and Removing the Nozzle
WARNING
Never operate your blower without a properly mounted
blower tube and nozzle, @ 5.6.4. Use only attachments
supplied or expressly approved by STIHL, @ 5.5.
To mount the nozzle:
► Align the hole on the nozzle (1) with the lug (3) on the
blower tube (2) and push them together until the nozzle
engages.
Once the nozzle and blower tube are assembled, keep
them connected during use and storage.
11.1 Adjusting the Control Handle
The control handle can be mounted to suit the height and
reach of the operator.
To adjust the position of the control handle:
► Switching off the blower, @ 15.2.
► Open the clamping lever (1).
► Move the control handle (2) to the most comfortable
position.
► Close the clamping lever.
11
12
0000099094_001
3
1
2
0000097050_001
11 Adjusting the Blower
1
2
0000-GXX-B941-A0