17 During Operation
To test the controls:
► Remove the battery.
► Attempt to depress the trigger switch.
If the trigger switch can be depressed without first 
unlocking the retaining latch, take the blower to an 
authorized STIHL servicing dealer to be repaired before 
use.
► Press down on the Ergo-Lever. Make sure it moves freely 
and springs back into place when released.
► Unlock the retaining latch by pushing it forward and 
depressing the Ergo-Lever. When you release the 
retaining latch, it should remain unlocked as long as you 
hold the Ergo-Lever.
► Insert the battery.
► Hold the blower firmly with one hand on the control 
handle. While pushing the retaining latch forward, 
squeeze the trigger switch with your index finger.
The blower should switch on. If it does not, take the blower 
to an authorized STIHL servicing dealer to be repaired 
before use.
► Release the trigger switch.
The blower should switch off.
If the blower does not switch off after you release the 
trigger switch, remove the battery and take the blower to 
an authorized STIHL servicing dealer to be repaired 
before use.
17.1 Using the Blower
WARNING
To reduce the risk of personal injury, never work with the 
blower in the rain or in wet or damp conditions, @ 5.5. 
Always wear proper clothing and protective apparel, 
including proper eye protection, @ 5.4. Never direct the air 
flow toward bystanders. Keep bystanders at least 16 ft. 
(5 m) away from the work area, @ 5.6.4. Work carefully and 
maintain proper control of the blower.
The blower is designed for single-handed operation with 
either the right or left hand.
► Hold the unit firmly with your hand, keeping the handle 
cradled between your thumb and fingers.
► Direct the air flow at the edges of the pile of material to be 
blown.
NOTICE
Never direct the air flow toward objects such as vehicles or 
windows that are less than 16 ft. (5 m) away.
Observe all applicable laws, regulations, standards and 
ordinances.
18.1 Preparing for Transportation or Storage
WARNING
To reduce the risk of personal injury from unintended 
activation or unauthorized use, switch off the motor and 
remove the battery before transporting the blower or putting 
it down.
To prepare the blower for transportation or storage:
► Switch off the blower, @ 15.2.
► Remove the battery, @ 14.2.
17 During Operation
18 After Finishing Work