EasyManua.ls Logo

Stihl GHE 250 - Technical specifications; Troubleshooting

Stihl GHE 250
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0478 201 8313 B - EN
28
Fault:
Motor does not start
Possible cause:
Motor overload protection activated
No mains voltage
Electric cable, plug, plug connector or
switch defective
Feed chute not properly closed - safety
cut-off switch actuated (motorstop)
Blade disc blocked
Locking device is not reset
Remedy:
Allow machine to cool down (Ö 8.6)
Check power cable and fuse
# (Ö 10.1)
Check cable, plug, connector and
switch and replace if necessary (by
electrician) # (Ö 10.1)
Close feed chute properly and tighten
screws (Ö 11.2)
Remove feed chute and remove
shredder deposits from the housing
(Important: disconnect the power cable)
(Ö 11.3)
Reset locking device (Ö 11.4)
Fault:
Reduced shredding performance
Possible cause:
Blunt blades
Remedy:
Reverse, re-sharpen or replace
shredding blades # (Ö 11.7)
16. Technical specifications
GHE 150.0/GHE 250.0/GHE 250.0 S:
Motor, design Electric motor
Power 2200 W
Amperage rating 10 A
Rated voltage 230 V~
Speed 2800 rpm
Main fuse
1
10 A
Frequency 50 Hz
Protection class I
Type of protection Splash proof
(IPX4)
Operating conditions P40
40 s load time
60 s idle time
GHE 150.0:
In accordance with
Directive
2000/14/EC:
Guaranteed sound
power level L
WAd
99 dB(A)
In accordance with
Directive
2006/42/EC:
Sound pressure level
at workplace L
pA
89 dB(A)
Uncertainty K
pA
2 dB(A)
Bolt tightening torques:
Blade disc 50 Nm
Reversible blade 10 Nm
Weight 27 kg
L/W/H 95/48/114 cm
GHE 250.0/GHE 250.0 S:
In accordance with
Directive
2000/14/EC:
Guaranteed sound
power level L
WAd
103/100 dB(A)
In accordance with
Directive
2006/42/EC:
Sound pressure level
at workplace L
pA
92/90 dB(A)
Uncertainty K
pA
3dB(A)
Bolt tightening torques:
Blade disc 50 Nm
Reversible blade 10 Nm
Shredding blades
2
10 Nm
Weight 29/28 kg
L/W/H 107/48/143 cm
1) Caution!
In the case of mains fuses of less
than 15 A, these may be tripped dur-
ing start-up or in the case of high
load operation of the machine.
2) For model GHE 250.0
17. Troubleshooting
# If necessary, contact a specialist
dealer; STIHL recommends STIHL
specialist dealers.