Other Useful Information (Cont.)
Fig. 6
WARNING!
Clean the appliance parts with water only; do not use
hard/sharp-edged objects for cleaning.
Do not operate the dryer without the air condenser unit.
During drying, water may collect between the window
and the seal, but this does not affect performance.
Emptying the condensate container
Holding the condensate container with two hands, pull it
out of the dryer housing, tilt it over a sink and pour out the
condensate water (Fig. 5).
Insert the empty condensate container back into its space.
Fig. 5
WARNING!
Empty the condensate container after each use. If the
container is full during the drying process, the program
will be paused and the icon will illuminate. After you
have emptied the container, you can restart the dryer
by pressing the START/PAUSE button.
Do not drink the condensate water.
Do not use the dryer without the condensate container.
Cleaning the air condenser/heat exchanger
Clean the air condenser unit approximately once every
three months, if the appliance is used frequently. Follow the
illustrations in Fig. 6 and clean it carefully, so that the air
condenser unit does not get damaged in the process.
Place an absorbent cloth under the maintenance cover
to catch any residual water which may escape.
Push down the handles to the maintenance cover and
open it completely.
To unlock the air condenser unit, rotate the locking
levers. Turn up the left lever and turn down the right one.
Pull out the air condenser/heat exchanger.
Clean the air condenser/heat exchanger completely and
drain it thoroughly. Be careful with the sharp edges at
the sides to avoid injury.
Clean the seals.
Re-insert the air condenser unit, making sure the handle
is at the bottom.
Turn both locking levers to the locking position.
Close the maintenance cover until it locks into position.