Rev: 2020 3A ©2020 Store It Cold, LLC 8
STEP 4 Find and free your A/C’s Temperature Sensor. It’s the only thing attached to the front fins/grill of your air
conditioner.
On Mini Split air conditioning units this sensor is often not in front of the fins of the indoor unit. It may be
tucked into a plastic cover underneath or to the side of the unit. For pictures and examples of Mini Split
installations please visit our library section at: www.storeitcold.com/support-library
If your A/C has a clip built into the sensor to hold the sensor in the fins, remove the sensor from the clip
and free it enough to reach the side of the A/C - DO NOT use the plastic mounting clip for this installation!
STEP 5 Using ONLY a 2” square piece of regular Aluminum
foil, place the CoolBot Heater Cable (red tip) next to
the A/C’s Temperature Sensor (from STEP 4).
Keep together next to each other, pointing in the
same direction, and wrap them tightly with the foil
into a bundle.
Make sure the bundle does NOT hang in front of the
A/C fins or hangs directly in front of the air flow of the
air conditioner It should hang free, to the side or
below the A/C not touching anything cold or metal.
You can put a wire tie or zip tie around the 2 cables (1
inch before the foil bundle) to keep the cables from
getting pulled apart.
STEP 6
IMPORTANT!
If your A/C has a Secondary Sensor, IT MUST BE UNPLUGGED.
Window LG (except dual Inverter models) and HAIER units DO NOT have Secondary Sensors (skip to STEP 7).
Most GE, Danby, Frigidaire, Arctic King, etc. A/C units over 10K BTUs have a Secondary Sensor.
Most “Mini-Split air conditioners have Secondary Sensors. See Mini Split Installation Guide
Use just 1 layer of electrical tape to attach the end of the Secondary Sensor to the OUTSIDE of the aluminum foil
connection from STEP 5. See picture below.
For videos, guide and pictures on how to locate the secondary sensor go to: https://www.storeitcold.com/support
Main A/C Sensor
Secondary A/C Sensor