3. After all floor panels are level, firmly and securely lock all floor panels together with the Hex
Wrench provided in your installation package. Turn it approximately ¾ of a full turn and
repeat until all floor panels are securely locked together.
4. DO NOT START YOUR WALLS UNTIL YOU ARE CERTAIN THAT THE FLOOR ASSEMBLY IS
COMPLETELY LEVEL (FRONT TO BACK AND LEFT TO RIGHT). Begin with two corner panels.
Usually the left back corner is a good place to start. Make sure that the top of each wall
adjacent panel is flush with each other. Use the wrench to secure the wall panels to the floor
and then lock the wall panels together to start the wall. Check for alignment to make sure
the panels are flush with the floor, corners and each other as you proceed. If the wall panels
have a stair-step appearance at the top, the floor is not level. In that case, stop immediately
and follow the previous instructions on leveling the floor (Step 2).