MACHINE OPERATION
STORMCHASER 86038660 03/29/07
EMPTYING AND CLEANING
3-4
Always use defoamer
if foaming occurs.
Foam will suspend large particles that may
damage vacuum(s) as well as allow liquid
into the vacuum motor(s) without activating
the float shutoff.
1. Before proceeding, make certain that the
nozzle is functioning properly.
a. To check, hold the wand about one foot
above the surface to be cleaned and
open the wand valve. A full spray should
be observed from the nozzle.
b. If the nozzle is not showing a full spray
pattern, adjust nozzle for proper pattern,
clean, or replace nozzle.
2. Normally, chemical is applied on the push
stroke while vacuuming is done on the pull
stroke. For heavily soiled carpets the hand
tool may be used in the scrubbing manner,
applying chemical in both the push and pull
stroke. A
LWAYS FINISH UP AN AREA WITH A
VACUUM PULL STROKE
.
3. When cleaning, keep the working opening
(wand mouth) flat on the surface being
cleaned. Keep the wand moving when the
valve is open.
4. The shutoff float inside the recovery tank will
impede the vacuum flow when the tank is
full. When this occurs, empty the recovery
tank. Do this by opening the dump valve
located at the back of the machine. NOTE:
Dispose of waste in a proper manner which
would not violate any Local, State or Federal
law.
5. Once the recovery tank has been emptied,
you may once again proceed with cleaning.
Operating Vacuum after shutoff has activated could
draw water directly into the vac motor. This will cause
damage to the motor, therefore voiding your
warranty.
A
LWAYS TEST CARPET FOR COLOR FASTNESS IN AN
INCONSPICUOUS PLACE
. Also, to avoid prolonged
drying times, do not spray too much solution in any
one area.
SHUT DOWN AND STORAGE
1. Turn Switch OFF. Empty recovery tank
completely and rinse several times to
remove any dirt or debris that may be left
behind.
2. Drain any unused cleaning solution from
solution tank and rinse with clean water to
remove any suds left behind by the cleaning
chemicals. NOTE: Dispose of waste in a
proper manner which would not violate any
Local, State or Federal law
3. Run a small amount of clean water through
pump if chemicals were used. This will help
insure the life of your pump.
4. Check the spray jet on the cleaning tool for
full spray pattern and inspect vac head for
any obstructions.
5. Remove as much moisture from system
before storing in cold climates. Excess water
may freeze during storage and crack internal
components, causing damage to the unit.
Before making any adjustments or performing
any maintenance to your machine, disconnect the
power cord from the electrical source.
CAUTION
!
WARNING
!
CAUTION
!