Operations Model 6DS-SP Planarizer
3 - 64 Version 4.0 - February 1998
8. Clean and dry the table with a soft cloth:
a. Feel the table by hand for adhesive residue.
b. Remove remaining residue with mild solvent.
c. Dry with soft cloth.
Installation
Install the new pad:
1. Place a new pad on the clean table (backing side down) and
center it.
2. Peel back the backing three to four inches and fold it under
(toward the center of the pad).
3. While continuing to maintain alignment, press the exposed
adhesive portion of the pad down onto the table.
4. Lift the backed portion of the pad and peel off the remaining
backing.
5. Working from the previously placed portion of the pad, smooth
the remaining pad into place.
Use a plastic roller to help smooth out bubbles.
Note: If you can’t get the bubbles out, start over with a new pad.
A quality product cannot be produced with a bubbled pad!