Strasbaugh Operator Functions
Version 4.0 - February 1998 3 - 93
Left Cleaning Station Pad Pressure
Tools Required
none
PROCEDURE FOR SETTING PRESSURE
1. Turn the machine power to OFF by pressing the red <EMERG
OFF> button located on the control panel.
2. Remove the Left Front Service Door.
3. Find the pneumatic regulator positioned under Solenoid 2 of
the valve panel located inside the Left Front Service Door.
4. Rotate the adjustment knob of the regulator until the gauge
displays the desired value.
Note: Refer to the table above for pad pressures and their
associated cylinder pressure values.
5. Replace the door.
6. Power up and home the machine.
Right Cleaning Station Pad Pressure
Repeat as for left cleaning station, substituting Solenoid 3 for Solenoid
2 in Step 3 of the procedure shown above.