Strasbaugh Troubleshooting
Version 4.0 - February 1998 5 - 39
“CONDITIONING ARM POSITION ERROR- # 50
Problem
Indicator
Problem
Location
Component/ Cause
Resolution
ERROR
MESSAGE
Control
Computer
Screen
(1) Arm unhomed.
(2) Arm not in park
position.
(3) The conditioning
arm is not in park
position.
(1a) Home the arm.
(2a) At the Auto Polish
Menu, move the arm to
park position.
(3a) Check related
input at the
Diagnostics menu. It
should be:
INPUT 22 - ON
(3b) Perform the
Conditioning Arm
calibration procedures
(refer to the Software
Calibration chapter of
the 6DS-SP
Maintenance manual).
MAINTENANCE