Strasbaugh Troubleshooting
Version 4.0 - February 1998 5 - 49
“TABLE DRAIN OVERFLOW FAULT- # 104
Problem
Indicator
Problem
Location
Component/ Cause
Resolution
ERROR
MESSAGE
Control
Computer
Screen
(1) Table drain
clogged.
(2) Sensor
malfunction.
(1a) Let cycle finish.
(1b) Clean up spillage,
if any.
(1c) Clean out table
drain basket.
OPERATIONS
(2a) Check and adjust
sensor.
MAINTENANCE
“SLURRY 1 SUPPLY LOW OR ABSENT- # 105
“SLURRY 2 SUPPLY LOW OR ABSENT- # 106
Problem
Indicator
Problem
Location
Component/ Cause
Resolution
ERROR
MESSAGE
Control
Computer
Screen
(1) Slurry tank.
(2) Sensor
malfunction.
(1a) Refill as needed.
OPERATIONS
(2a) Check and adjust
sensor.
MAINTENANCE