Strasbaugh Physical Description
Version 4.0 - February 1998 3 - 5
OPERATOR DOOR INTERLOCKS
Opening a polish section operator door during a cycle interrupts and suspends
the cycle. To continue the cycle, close the operator door and press the CYCLE
START pushbutton on the control panel. If the cycle had been polishing,
polishing will end but the rest of the cycle can be continued.
Opening an elevator access operator door will not halt the cycle, but it will
prevent elevator and robot movements, pausing the cycle when those movements
are required. (Close the door to continue.)
For further information on the interlock safety switches, see the Power
Distribution chapter of the 6DS-SP Maintenance and the Troubleshooting
chapter of either the 6DS-SP Operations or Maintenance manual.