Strasbaugh Physical Description
Version 4.0 - February 1998 3 - 7
The Right Top Emergency Off Button (3) is an emergency off switch, used for
instantly stopping all machine motion and turning off control power at any time.
The Control Panel (1) and Flat Panel Screen and Keypad (2) of the operator
interface are described in detail later in this chapter. Note that the operator
interface may be located at either the front or left side of the machine cabinet.
Options available include dual front and side interfaces and a mobile remote
interface.
The Left Side Polish Section Door (4) and the Right Side Polish Section Door
(5) are fitted with switches to sense whether the doors are fully closed.
The polish section operator doors must be closed in order for the machine
to respond when the CYCLE START pushbutton is depressed during an
auto polish cycle or slurry system flush.
The elevator access doors must be closed to permit elevator and robot
movements. If not, an automatic cycle may pause until the door is closed.
To open either polish section operator door requires pulling the latch assembly
toward the operator and then pushing the door aside in its slider track. The Left
Operator Door is latched closed by an air cylinder whenever the shuttle or
second table assembly is in motion.