Operations Model 6DS-SP Planarizer
2 - 6 Version 4.0 - February 1998
OPERATOR DOOR INTERLOCKS
Opening a polish section operator door during a cycle interrupts and
suspends the cycle. To continue the cycle, close the operator door and press
the CYCLE START pushbutton on the control panel. If the cycle had been
polishing, polishing will end but the rest of the cycle can be continued.
Opening an elevator access operator door will not halt the cycle, but it
will prevent elevator and robot movements, pausing the cycle when those
movements are required. (Close the door to continue.)
For further information on the interlock safety switches, see the Power
Distribution chapter of the 6DS-SP Maintenance and the Troubleshooting
chapter of either the 6DS-SP Operations or Maintenance manual.