Maintenance Model 6DS-SP Planarizer
10 - 26 Version 4.0 - February 1998
BRIDGE
BRIDGE HOME POSITION
CALIBRATION
CALIBRATION VARIABLE(S) SET DURING THIS PROCEDURE
1 Bridge home position
Nominal value: -35 in.
The distance in negative inches from the primary
table center to the home position.
A. BEFORE YOU BEGIN
Tools Required
• precision scale (accurate to .03125 in.)
Turn Machine Power On and Perform Home Sequence Routine
Follow the procedures detailed in the Operator Functions chapter of the 6DS-SP
Operations manual.