Maintenance Model 6DS-SP Planarizer
10 - 40 Version 4.0 - February 1998
2. Calculate the new calibration value for the bridge table 2 position
variable:
NEW =
CALIBRATION
VALUE
Current Value + [(Right Side Meas. - Left Side Meas.) / 2]
(from screen)
Example:
NEW = - 36.1 + [( .4.0 - 4.5) / 2]
CALIBRATION
VALUE
NEW = - 36.1 + [( - 0.5) / 2]
CALIBRATION
VALUE
NEW = - 36.1 + ( - .25)
CALIBRATION
VALUE
NEW = - 36.35
CALIBRATION
VALUE
WARNING: Always raise the spindles before changing any
bridge position variable.
3. At Page 2 of the Manual Control Menu, select Left Spindle Up/Down
and choose Up to raise the left spindle.
4. Select Right Spindle Up/Down and choose Up to raise the right spindle.
5. Enter the new calibration value for variable 16, Bridge table 2 position.
Example: - 36.35
WARNING: The value for the table 2 bridge home position
variable is always negative. A positive number
may do severe damage to the machine!
6. At Page 1 of the Manual Control Menu, select Bridge Move and choose
Pol Tbl 2 to move the bridge to its table 2 position.
7. Lower both spindles.
8. Remeasure to check the new adjustment. Repeat the adjustment
procedure as needed until the goal is met.