Maintenance Model 6DS-SP Planarizer
13 - 20 Version 4.0 - February 1998
ELEVATOR TANKS WONT HOLD WATER
Problem
Indicator
Problem
Location
Component/ Cause Resolution/
Responsibility
ELEVATOR
TANKS WONT
HOLD WATER
Elevator tanks
Manual Drain
Valve:
(1) Elevator drain
valve not closed.
Auto Filling
Option:
(2) Cassette missing
or sensor arm up.
(3) Valve
malfunction.
Manual Drain Valve:
(1a) Close elevator
drain valve after
draining.
Auto Filling Option:
(2a) Place cassette on
elevator and lower
sensor arm.
OPERATIONS
(3a) Check and replace
valve.
MAINTENANCE

Related product manuals