Maintenance Model 6DS-SP Planarizer
13 - 42 Version 4.0 - February 1998
“SEND CASSETTE(S) NOT ACTIVE- # 53
Problem
Indicator
Problem
Location
Component/ Cause
Resolution
ERROR
MESSAGE
Control
Computer
Screen
(1) Control
computer not
finding active
receive cassette.
(1a) Place a cassette on
a receive elevator.
OPERATIONS
(1b) Lower the cassette
sensor arm.
(1c) Test to see if the
cassette sensor is
tripped when the
cassette sensor arm is
lowered. If not, adjust
the switch.
MAINTENANCE
“ROBOT TOP/BOTTOM NOT AT ZERO- # 54
Problem
Indicator
Problem
Location
Component/ Cause
Resolution
ERROR
MESSAGE
Control
Computer
Screen
(1) Elevator
operator door open.
(2) Robot arms not
homed.
(1a) Close the door.
(2a) Rehome all robot
axes at the Servo
Initialization menu.
OPERATIONS