EasyManua.ls Logo

Struers Tegramin-25 - User Manual

Struers Tegramin-25
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Manual No.: 16037001
Date of Release 11.03.2013
Tegramin-25/-30
Instruction Manual

Table of Contents

Questions and Answers

  • T
    Timothy NelsonAug 12, 2025
    What to do if the surfaces are being damaged in Struers Laboratory Equipment?
    • L
      Laura RobinsonAug 12, 2025
      If the surfaces are being damaged when using Struers Laboratory Equipment, it could be due to several reasons. The specimen may have burrs or sharp edges that need to be removed. Alternatively, the force applied to the specimen might be too high, or the specimen area might be too small. Try removing burrs and sharp edges, and lower the applied force to resolve this issue.
  • J
    Jeffrey TorresAug 16, 2025
    How to fix 'process cannot be started' error in Struers Laboratory Equipment?
    • V
      Vanessa MurphyAug 16, 2025
      If the process cannot be started on your Struers Laboratory Equipment, and you are seeing error messages, it might be because the flexible specimen holder is too close to the surface. To fix this, try changing the force, using higher specimens, or changing the configuration.
  • B
    Brenda MelendezAug 20, 2025
    What to do if pins are touching the surface on Struers Laboratory Equipment?
    • J
      Jeffrey CrawfordAug 20, 2025
      If the pins on the flexible specimen holder are touching the preparation surface while using Struers Laboratory Equipment, it's likely that the force setting is too high, or the specimens are too low. You can decrease the force or increase the specimen height.
  • J
    Jackson BowmanAug 23, 2025
    Why is the polishing cloth life so short on Struers Laboratory Equipment?
    • M
      Miss Karen BarnesAug 25, 2025
      If you are experiencing a short lifetime of the polishing cloth with your Struers Laboratory Equipment, it might be because the polishing cloth is too soft. Try using a harder polishing cloth.
  • J
    Joseph ColeAug 27, 2025
    What to do if specimens fall out of Struers Laboratory Equipment?
    • W
      Wendy StewartAug 27, 2025
      If the specimens fall out of the flexible specimen holder in your Struers Laboratory Equipment, it could be due to incorrect placement or insufficient force. Increase the force.
  • J
    jimmyflemingAug 31, 2025
    Why do specimens develop a pencil shape in Struers Laboratory Equipment?
    • E
      Erin NelsonAug 31, 2025
      If the specimens develop a pencil shape when using Struers Laboratory Equipment, it could be due to several reasons: incorrect placement, a sample area that is too small, a specimen that is too high, or a specimen geometry that is round and solid. Turn the specimen and repeat the step.
  • K
    Kathleen BarnesSep 3, 2025
    What causes pins to stick in Struers Laboratory Equipment?
    • F
      Franklin FlemingSep 3, 2025
      If the pins on the flexible specimen holder get stuck to the bottom plate of your Struers Laboratory Equipment, it's likely because the flexible specimen holder is dirty. Clean the flexible specimen holder.
  • A
    Alexandria StewartSep 7, 2025
    Why is it hard to insert the specimen holder in Struers Laboratory Equipment?
    • A
      Angela VillanuevaSep 7, 2025
      If it is difficult to insert the flexible specimen holder in the Struers Laboratory Equipment, the coupling might be worn out. Check the coupling.

Summary

FCC Notice

Safety Precaution Sheet

Disposal

Getting Started

Checking the Contents

Lists all items included in the packaging for the Tegramin machine.

Unpacking Tegramin

Provides instructions for safely removing the Tegramin machine from its crate.

Placing Tegramin

Guidance on positioning the Tegramin machine on a stable and suitable surface.

Getting Acquainted with Tegramin

Familiarization with the Tegramin machine's components and external controls.

Rear of Tegramin

Identification of connection ports and components located on the rear panel of the Tegramin.

Supplying Water

Connection to Water Mains

Instructions for connecting the water inlet hose to the mains tap for the Tegramin.

Connection to Water Outlet

Instructions for connecting the water outlet hose to a drain for the Tegramin.

Adjusting the Water Flow

How to adjust water flow using manual and throttle valves on the Tegramin.

Connecting a Recirculation Cooling Unit

Steps for connecting an optional cooling unit to the Tegramin machine.

Connecting the Communication Cable

Connecting the communication cable to the Cooli Control Box for the Tegramin.

Installing the Shift Valve (Accessory)

Instructions for installing the shift valve for drain management with the Tegramin.

Compressed Air Connections

Emptying the Water; Oil Filter

Procedure for periodically draining the compressed air filter on the Tegramin.

Supplying Power

Single-phase Supply

Details and wiring instructions for single-phase power connection to the Tegramin.

2-phase Supply

Details and wiring instructions for two-phase power connection to the Tegramin.

Connection to the Machine

How the power cable connects to the main unit of the Tegramin.

Mounting the Dosing Modules

OP dosing

Specific instructions for mounting OP pump modules onto the Tegramin.

Basic Operation of Tegramin

Front Panel

Overview of the Tegramin machine's front control panel and its layout.

Front Panel Controls

Explains the function of each key and control on the Tegramin's front panel.

Reading the Display

How to interpret information and status shown on the Tegramin's display.

Manoeuvring in the menu structure

Instructions on navigating the Tegramin's software menus using the controls.

Acoustic Signals

Explains the meaning of different audio feedback (beeps) from the Tegramin machine.

Software Settings

Changing the Language

How to change the display language of the Tegramin's software interface.

Editing Numeric Values

How to change numerical parameters within the Tegramin's software settings.

Editing Alphanumeric Values

How to change text-based parameters in the Tegramin's software settings.

Operation Mode

Setting user levels (Production, Development, Configuration) for Tegramin operation.

New Pass Code

Procedure for setting a new access pass code for the Tegramin machine.

Preparation Process Setup

Metalog Guide

Reference to the Struers Metalog Guide for materialographic preparation methods.

Mounting a Disc

Instructions for correctly placing the preparation disc onto the Tegramin.

Selecting a preparation mode

Choosing between different preparation modes for the materialographic process.

Selecting a preparation method

Choosing a specific preparation method from a selected group on the Tegramin.

Creating a Preparation Method

Steps to create a new custom preparation method for the Tegramin.

Modifying an existing preparation method

How to edit and save changes to existing preparation methods on the Tegramin.

Locking a preparation method

How to prevent accidental changes or deletion of a selected preparation method.

Unlocking a preparation method

How to re-enable a locked preparation method for modification on the Tegramin.

Starting the Preparation Process

How to initiate a selected preparation cycle on the Tegramin.

Stopping the Process

How to halt a preparation process before its scheduled completion on the Tegramin.

Spin Function

Using the spin function to quickly dry the preparation disc on the Tegramin.

Operating Tegramin

Inserting Specimen Holders or Specimen Mover Plates

Instructions for fitting specimen holders or mover plates into the Tegramin machine head.

Manual Preparation

How to perform a materialographic preparation process manually using the Tegramin.

Recommendations for Grinding Single Specimens

Tips for optimizing the grinding process for single specimens on the Tegramin.

Accessories and Consumables

Trouble-shooting

Maintenance

Daily Service

Daily cleaning and checks to ensure proper function of the Tegramin machine.

Weekly Service

Weekly tasks for upkeep and cleaning of the Tegramin machine.

Cleaning of Tubes

Procedure for flushing and cleaning the liquid delivery tubes on the Tegramin.

Cleaning the Bowl

Instructions for cleaning the preparation bowl on the Tegramin machine.

Cleaning of Specimen Mover Head

Cleaning procedures for the specimen mover head assembly of the Tegramin.

Calibration of Pump Capacity

Calibrating the liquid dosing pumps for accurate delivery on the Tegramin.

Adjustment of Tube Cleaning Time

Setting the duration for tube cleaning and refilling cycles on the Tegramin.

Aligning the specimen holder;mover plate

Adjusting the alignment of the specimen holder relative to the preparation disc.

Reset Functions

Resetting machine functions or configuration to factory default settings.

Reset methods

Resetting specific preparation methods to their default states on the Tegramin.

Reset configuration

Resetting all system configuration parameters to factory defaults on the Tegramin.

Service Information

Accessing detailed operational and diagnostic information about Tegramin machine components.

Service Check

Information and reminders regarding scheduled service checks based on Tegramin operating hours.

Changing Tubes

Procedure for replacing pump tubes, especially silicone tubes, on the Tegramin.

Technical Data

Struers Tegramin-25 Specifications

General IconGeneral
BrandStruers
ModelTegramin-25
CategorySander
LanguageEnglish

Related product manuals