Manual No.: 16037001
Date of Release 11.03.2013
Tegramin-25/-30
Instruction Manual

Table of Contents

Questions and Answers

  • J
    Jessica AdamsAug 13, 2025
    What to do if the surfaces are being damaged in Struers Laboratory Equipment?
    • B
      Brandon OrtizAug 14, 2025
      If the surfaces are being damaged when using Struers Laboratory Equipment, it could be due to several reasons. The specimen may have burrs or sharp edges that need to be removed. Alternatively, the force applied to the specimen might be too high, or the specimen area might be too small. Try removing burrs and sharp edges, and lower the applied force to resolve this issue.
  • P
    Perry Richardson DDSAug 17, 2025
    How to fix 'process cannot be started' error in Struers Laboratory Equipment?
    • D
      David SloanAug 17, 2025
      If the process cannot be started on your Struers Laboratory Equipment, and you are seeing error messages, it might be because the flexible specimen holder is too close to the surface. To fix this, try changing the force, using higher specimens, or changing the configuration.
  • D
    David EspinozaAug 21, 2025
    What to do if pins are touching the surface on Struers Laboratory Equipment?
    • J
      James StewartAug 21, 2025
      If the pins on the flexible specimen holder are touching the preparation surface while using Struers Laboratory Equipment, it's likely that the force setting is too high, or the specimens are too low. You can decrease the force or increase the specimen height.
  • K
    Katherine JonesAug 25, 2025
    Why is the polishing cloth life so short on Struers Laboratory Equipment?
    • P
      patrick74Aug 26, 2025
      If you are experiencing a short lifetime of the polishing cloth with your Struers Laboratory Equipment, it might be because the polishing cloth is too soft. Try using a harder polishing cloth.
  • R
    Ronald CaldwellAug 28, 2025
    What to do if specimens fall out of Struers Laboratory Equipment?
    • K
      Kristin SchroederAug 28, 2025
      If the specimens fall out of the flexible specimen holder in your Struers Laboratory Equipment, it could be due to incorrect placement or insufficient force. Increase the force.
  • S
    Sharon SullivanSep 1, 2025
    Why do specimens develop a pencil shape in Struers Laboratory Equipment?
    • I
      iburtonSep 2, 2025
      If the specimens develop a pencil shape when using Struers Laboratory Equipment, it could be due to several reasons: incorrect placement, a sample area that is too small, a specimen that is too high, or a specimen geometry that is round and solid. Turn the specimen and repeat the step.
  • K
    Kimberly MillerSep 5, 2025
    What causes pins to stick in Struers Laboratory Equipment?
    • M
      Michael MaySep 5, 2025
      If the pins on the flexible specimen holder get stuck to the bottom plate of your Struers Laboratory Equipment, it's likely because the flexible specimen holder is dirty. Clean the flexible specimen holder.
  • A
    Alicia GarciaSep 8, 2025
    Why is it hard to insert the specimen holder in Struers Laboratory Equipment?
    • B
      bbaxterSep 9, 2025
      If it is difficult to insert the flexible specimen holder in the Struers Laboratory Equipment, the coupling might be worn out. Check the coupling.

Summary

Safety Precaution Sheet

Getting Started

Getting Acquainted with Tegramin

Supplying Water

Connection to Water Mains

Guidance on connecting the water inlet hose to the mains water tap.

Connection to Water Outlet

Instructions for connecting the water outlet hose to a suitable drain.

Supplying Power

Single-phase Supply

Instructions for connecting single-phase power supply, including plug wiring.

2-phase Supply

Instructions for connecting two-phase power supply, including plug wiring.

Connection to the Machine

How to connect the power cable to the Tegramin machine.

Mounting the Dosing Modules

Basic Operation of Tegramin

Front Panel Controls

Detailed explanation of each button and function on the front panel.

Software Settings

Operation Mode

Changing Operation Mode

Steps to change the operational mode (Production, Development, Configuration).

Preparation Process Setup

Selecting a preparation mode

How to choose between different preparation modes (e.g., specimen holder, single specimen).

Selecting a preparation method

Guidance on choosing specific preparation methods from available groups.

Creating a Preparation Method

Steps to create a new custom preparation method.

Modifying an existing preparation method

How to adjust and save changes to existing preparation methods.

Starting the Preparation Process

How to initiate a selected preparation method.

Operating Tegramin

Inserting Specimen Holders or Specimen Mover Plates

Guidance on inserting specimen holders or mover plates into the machine head.

Manual Preparation

Instructions for performing manual grinding and polishing operations.

Trouble-shooting

Maintenance

Calibration of Pump Capacity

How to calibrate individual dosing pumps for accurate liquid delivery.

Reset Functions

Struers Tegramin-30 Specifications

General IconGeneral
BrandStruers
ModelTegramin-30
CategorySander
LanguageEnglish