1212 Emergency Care Stretcher
Operations Manual
For Parts or Technical Assistance
800–327–0770
Renaissance Series

Other manuals for Stryker Renaissance Series

Questions and Answers

  • M
    Marcus MurphyAug 3, 2025
    What to do if Stryker Medical Equipment jack will not pump up but the jack actuator rod does move when the pump pedal is activated?
    • A
      Amber WellsAug 3, 2025
      If the Stryker Medical Equipment jack is not pumping up, but the actuator rod moves when the pump pedal is activated, the suggested solution is to replace valve #2. See page 13 for instructions.
  • J
    Joy WilliamsAug 8, 2025
    Why Stryker Medical Equipment jack will not hold in raised position?
    • B
      Brenda SteeleAug 8, 2025
      If your Stryker Medical Equipment jack won't hold in the raised position, check the linkage to ensure it's disengaged. If engaged, use a 7/16” socket or wrench to back off the nut until the jack drift stops. Should the jack still fail to hold, consider replacing valve #1, referring to page 12 for guidance.
  • B
    Bethany BurgessAug 13, 2025
    What to do if Stryker Medical Equipment jack will not pump up and the jack actuator rod does not move?
    • E
      Emily HughesAug 13, 2025
      If your Stryker Medical Equipment jack will not pump up and the jack actuator rod does not move, close the needle valve. If it still won't pump, replace valve #2 (see p. 13).
  • S
    Shelia SullivanAug 19, 2025
    How to fix Stryker Renaissance Medical Equipment jack that will not raise to full height?
    • S
      Sergio WrightAug 19, 2025
      If the Stryker Medical Equipment jack won't raise to full height, check for any leaks. Add hydraulic fluid as needed; refer to page 11 for instructions.
  • J
    Jennifer CainAug 23, 2025
    What to do if Stryker Renaissance jack will not hold in raised position?
    • M
      Melissa GarciaAug 23, 2025
      If your Stryker Medical Equipment jack fails to hold in the raised position, start by completely closing the needle valve. If the jack then holds, the solution is to replace valve #1, as detailed on page 14. However, if the jack still does not hold its position, proceed to replace valve #2, as instructed on page 15.
  • S
    Samuel ChurchAug 28, 2025
    Why Stryker Renaissance jack will not pump up and the jack actuator rod does not move?
    • D
      David RichardAug 28, 2025
      If the Stryker Medical Equipment jack won't pump up and the actuator rod remains stationary, begin by closing the needle valve. If the jack then pumps up, the remedy is to replace valve #1. Should the jack still fail to pump up after closing the needle valve, replace valve #3, as described on page 15.

Summary

Warning; Caution; Note Definitions

Warning Definition

Indicates potential risks to personal safety during operation.

Caution Definition

Highlights procedures to avoid equipment damage.

Operating Four-Sided Controls Base

Raise Litter (A)

Describes using pedal A to elevate the stretcher litter.

Raising and Lowering Litter Height

Raise Litter Height

Instructions on how to raise the stretcher litter using pedal A.

Lower Litter Height

Instructions on how to lower the stretcher litter using pedals B and C.

Trendelenberg;Reverse Trendelenberg Positioning

Trendelenberg Position

How to position the stretcher head-down using pedal B.

Reverse Trendelenberg Position

How to position the stretcher foot-down using pedal C.

Applying the Brake System

Engage Brakes (Control End)

Instructions for applying brakes via pedal D on the control end.

Engage Brakes (Non-Control End)

Instructions for applying brakes via pedal E on the non-control end.

Operating the Fowler;Knee Gatch

Crank Fowler;Knee Gatch

How to operate crank-based Fowler and Knee Gatch adjustments.

Pneumatic Fowler

How to operate pneumatic Fowler adjustments using handle A.

Using Siderails

Engaging Siderails

Instructions for raising and locking siderails using latch B.

Disengaging Siderails

Instructions for lowering and disengaging siderails using latch B.

Preventative Maintenance

Cleaning Procedures

Instructions for cleaning the stretcher surfaces and Velcro components.

Biannual Checklist

A comprehensive list of inspection points for bi-annual maintenance.

Damaged Merchandise

Claims for Damaged Goods

Procedure for filing claims for damaged merchandise within 15 days.

Damaged Shipment Acceptance

Instructions on not accepting damaged shipments unless noted on receipt.

Short Shipment Claims

Procedure for filing claims for short shipments within 30 days.

Stryker Renaissance Series Specifications

General IconGeneral
CategoryMedical Equipment
ManufacturerStryker
SeriesRenaissance
DisplayHigh-resolution touchscreen
Compatibilitysurgical instruments
PortabilityMobile
Softwaresurgical planning and navigation software

Related product manuals