Studer Innotec SA
VarioString
54 V 2.3 User manual
17 PARAMETER LIST
Level
User
ref.
Parameter
Factory value
User
value
Expert
14001
Battery charge current (VS-120)
120 Adc
Basic
14002
Configuration of PV modules (VS-120)
Automatic
Expert
14005
Floating voltage
54.4 Vdc
Expert
14006
Force phase of floating
-
Expert
14008
Absorption phase allowed
Yes
Expert
14009
Absorption voltage
57.6 Vdc
Expert
14010
Force absorption phase
-
Expert
14011
Absorption duration
120 min
Expert
14012
End of absorption triggered by the current
No
Expert
14013
Current threshold to end absorption phase
10 Adc
Expert
14017
Equalization allowed
No
Expert
14018
Force equalization
-
Expert
14019
Equalization before absorption phase
Yes
Expert
14020
Equalization current
80 Adc
Expert
14021
Equalization voltage
62.4 Vdc
Expert
14022
Equalization duration
30 min
Expert
14023
Equalization with fixed interval
Yes
Expert
14024
Days between equalizations
26 days
Expert
14025
End of equalization triggered by the current
No
Expert
14026
Current threshold to end equalization phase
10 Adc
Expert
14028
Force a new cycle
-
Expert
14029
Voltage level 1 to start a new cycle
48.8 Vdc
Expert
14030
Time period under voltage level 1 to start a new cycle
30 min
Expert
14031
Voltage level 2 to start a new cycle
47.2 Vdc
Expert
14032
Time period under voltage level 2 to start a new cycle
2 min
Expert
14033
Cycling restricted
Yes
Expert
14034
Minimal delay between cycles
1 hours
Expert
14035
Temperature compensation
-3 mV/°C/cell
Basic
14036
Synchronisation battery cycle with Xtender
Yes
Expert
14038
ON of the VarioString
-
Expert
14039
OFF of the VarioString
-
Expert
14040
Type of battery grounding
No control
Expert
14041
Type of PV grounding
No control
Expert
14042
Type of PV2 grounding
No control
Expert
14043
Type of MPP tracking algorithm PV
LSF
Expert
14044
PV voltage fixed (for PV in series)
700 Vdc
Expert
14045
Ratio of PV open circuit voltage
0.7
Expert
14046
Type of MPP tracking algorithm PV2
LSF
Expert
14047
PV2 voltage fixed
500 Vdc
Expert
14048
Ratio of PV2 open circuit voltage
0.7
Expert
14051
Reset daily solar production meters
-
Expert
14052
Reset daily min-max
-
Expert
14059
Reset of all VarioString
-
Basic
14067
Restore default settings
-
Inst.
14068
Restore factory settings
-
Inst.
14069
Parameters saved in flash memory
Yes
Expert
14071
Operating mode (AUX 1)
Automatic