Studer Innotec SA
VarioString
56 V 2.3 User manual
Level
User
ref.
Parameter
Factory value
User
value
Expert
14124
Combination of the events for the auxiliary contact
(AUX 2)
Any (Function OR)
Expert
14126
Activated in night mode (AUX 2)
No
Expert
14127
Delay of activation after entering night mode (AUX 2)
1 min
Expert
14128
Activation time for the auxiliary relay in night mode
(AUX 2)
1 min
Expert
14130
VarioString is OFF (AUX 2)
No
Expert
14131
Battery undervoltage (AUX 2)
No
Expert
14132
Battery overvoltage (AUX 2)
No
Expert
14133
Earth fault (AUX 2)
No
Expert
14134
PV error (48h without charge) (AUX 2)
No
Expert
14135
Overtemperature (AUX 2)
No
Expert
14136
Bulk charge phase (AUX 2)
No
Expert
14137
Absorption phase (AUX 2)
No
Expert
14138
Equalization phase (AUX 2)
No
Expert
14139
Floating (AUX 2)
No
Expert
14140
Reduced floating (AUX 2)
No
Expert
14141
Periodic absorption (AUX 2)
No
Expert
14143
Battery voltage 1 activate (AUX 2)
No
Expert
14144
Battery voltage 1 (AUX 2)
46.8 Vdc
Expert
14145
Delay 1 (AUX 2)
1 min
Expert
14146
Battery voltage 2 activate (AUX 2)
No
Expert
14147
Battery voltage 2 (AUX 2)
47.8 Vdc
Expert
14148
Delay 2 (AUX 2)
10 min
Expert
14149
Battery voltage 3 activate (AUX 2)
No
Expert
14150
Battery voltage 3 (AUX 2)
48.5 Vdc
Expert
14151
Delay 3 (AUX 2)
60 min
Expert
14152
Battery voltage to deactivate (AUX 2)
54 Vdc
Expert
14153
Delay to deactivate (AUX 2)
60 min
Expert
14154
Deactivate if battery in floating phase (AUX 2)
No
Expert
14156
Contact activated with the temperature of battery
(AUX 2)
No
Expert
14157
Contact activated over (AUX 2)
3 °C
Expert
14158
Contact deactivated below (AUX 2)
5 °C
Expert
14159
Only activated if the battery is not in bulk phase
(AUX 2)
No
Expert
14161
Contact activated with the SOC 1 of battery (AUX 2)
No
Expert
14162
Contact activated below SOC 1 (AUX 2)
50 % SOC
Expert
14163
Delay 1 (AUX 2)
12 hours
Expert
14164
Contact activated with the SOC 2 of battery (AUX 2)
No
Expert
14165
Contact activated below SOC 2 (AUX 2)
30%
Expert
14166
Delay 2 (AUX 2)
0.2 hours
Expert
14167
Contact activated with the SOC 3 of battery (AUX 2)
No
Expert
14168
Contact activated below SOC 3 (AUX 2)
20%
Expert
14169
Delay 3 (AUX 2)
0 hours
Expert
14170
Contact deactivated over SOC (AUX 2)
90 % SOC
Expert
14171
Delay to deactivate (AUX 2)
0.2 hours
Expert
14172
Deactivate if battery in floating phase (AUX 2)
No
Expert
14173
Reset all settings (AUX 2)
-
Expert
14174
Block manual programming (dip-switch)
No