700-2 SERIES (Tall Units)Starting W/ Serial #1759163
» Temperature Log Recall Mode
(Compartment &/or Evaporator temperature History)
1. With unit on, initiate Diagnostic Mode - Press either
COLD-
ER key & UNIT ON/OFF keys simultaneously, then release
3. Toggle through temperature readings by pressing COLDER
or WARMER key until desired thermistor temperature is
observed
4. Press WARMER key for that compartment and UNIT
ON/OFF simultaneously
NOTE: After performing the above key strokes (depending on
WARMER key chosen), the following will appear on the LCD.
Temperatures shown are for reference only, actual temperatures
may vary.
--1100
SERVICE (Illuminated)
0011
2 hour thermistor temperature average (at left) with index
number. Number 1 is most recent 2 hour period.
- Press WARMER key in multiple keystrokes to toggle up
through indexes, from 1 to 168.
--1122 116688
2 hour thermistor temperature average (at left) with index
number. Number 168 is oldest recorded 2 hour period.
- Press COLDER key in multiple keystrokes to toggle down
through indexes, from 168 to 1.
NOTE: Possible event indicators during Temperature Log Recall
Mode is on next page. Temperature Log Recall Mode ends 10
seconds after last key stroke.

Other manuals for Sub-Zero 400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sub-Zero 400 Series and is the answer not in the manual?

Sub-Zero 400 Series Specifications

General IconGeneral
BrandSub-Zero
Model400 Series
CategoryRefrigerator
LanguageEnglish

Related product manuals