Integrated 
Integrated 
(700-
(700-
3
3
T
T
ALL)
ALL)
Series
Series
Icemaker Information
6-13
#3758412 - Revision B - December, 2006
ICEMAKER FAULT TESTING
Bypass 45-minute dwell by pressing ICE ON/OFF key to OFF
then ON.  Then depress icemaker switch & manually start ice-
maker by turning driver gear counter-clockwise with screw-
driver.
1 If icemaker starts & finishes cycle: 
(NOTE:  If >15°F (-9°C), icemaker will only complete 1
revolution.)
a. Visually inspect electrical connections at icemaker &
valve. Repair if necessary.
b. Check valve operation with test cord, if doesn't open,
replace.
c. Check thermostat.  Open: 48° (9°C) ± 6°, Close: 15°
(-9°C) ± 3°.  Replace icemaker if defective.
d. With icemaker in park position, check solenoid switch
terminals "C" & "NO" for continuity.  With ejector
between 8:00 & 10:00 position, check solenoid switch
terminals "C" & "NC" for continuity.  If no continuity for
either terminal check, replace icemaker.
2. If icemaker starts but does not finish cycle:
a. With icemaker in park position check holding switch ter-
minals "C" & "NC" for continuity.  Then with icemaker
ejector between 10:00 & 12:00, check holding switch
terminals "C" & "NO" for continuity.  If no continuity for
either terminal check, replace icemaker.  (Refer to
enclosed wiring diagram)
b. With icemaker in park position check shut-off switch
terminals "C" & "NO" for continuity.  With ejector
between 12:00 & 2:00 check shut-off switch terminals
"C" & "NC" for continuity. If no continuity for either ter-
minal check, replace icemaker. 
c. Check mold heater for 75-85Ω.  If outside range,
replace icemaker.
3 If icemaker motor does NOT start:
a. Lower shutoff arm
b. Check motor operation with test cord. If motor doesn't
run, replace icemaker.
c. Check power to & from icemaker switch. Reconnect or
repair connection or replace icemaker as necessary.
d. Check for 115V AC from control board. If power is pres-
ent check & repair connection.  If no power, replace
control board.
QUICK REFERENCE
• Water Fill Time - 6.3±.2 seconds 
• Fill Tube Heater Ohm - 2850-3890Ω
• Mold Heater Ohm - 75-85Ω
• Water Valve Ohm - 160-165Ω
• Thermostat - Open: 48° (9°C) ± 6°, Close: 15° (-9°C) ± 3°.
• Water Pressure Needed - 20-100 psi constant
Possible Problems
No / Slow Ice Production
1 Ice maker system switched OFF.  Switch ice system ON.
2  Shut off arm in up/OFF position.  Move to ON position.
3 Freezer too warm.  Check temp’s & see troubleshooting
guide in service manual.
4 Poor airflow over icemaker.  Remove obstructions.
5 Ice cube jam.  Remove ice & check water fill setting.
a. Water fill setting too low  (< 6.5 sec’s).  Adjust setting.
b. Water fill setting too high (> 7 sec’s).  Adjust setting.
6 Water froze in inlet tube.  Remove ice from tube.  Check
for 115VAC from control board; Fill tube heater = 2850-
3890Ω.
7 Water supply not constant 20-100 psi.  Instruct customer.
8 Water line to unit pinched/kinked.  Repair water line.
9 Saddle valve not installed correctly to supply line.
Reposition.
10 Saddle valve not fully open.  Open valve fully.
11 Icemaker wire/connections loose/broken.  Repair wiring.
12 Water valve wire/connections loose/broken.  Repair wiring.
13 Defective water valve. Check valve (160-165Ω), Replace
valve.
14 Thermostat wire/connections loose/broken.  Repair wiring.
15 TCO overheat or short.  Replace icemaker. 
16 See Icemaker Fault Testing.
No W
ater Fill
1 Water supply switched OFF.  Switch supply water line ON.
2 Water line to unit pinched/kinked.  Repair water line.
3 Saddle valve not installed correctly to supply line.
Reposition.
4 Water froze in inlet tube.  Remove ice from tube.  Check
for 115VAC from control board; Fill tube heater = 2850-
3890Ω.
5 Water valve wire/connections loose/broken.  Repair wiring.
6 Defective water valve. Check valve (160-165Ω), Replace
valve.
Overflows / Ice Block Forms in Bucket / Oversized Cubes
1 Icemaker not level.  Level icemaker.
2 Unit not level.  Level unit
3 Water supply not constant 20-100 psi.  Instruct customer.
4 Water fill setting too high (> 7 sec’s).  Adjust setting.
5 Water fill setting too low  (< 6.5 sec’s).  Adjust setting.
6 Defective water valve. Check valve (160-165Ω), Replace
valve.
Ice Cubes Hollow or Small
1 Icemaker not level.  Level icemaker.
2 Unit not level.  Level unit
3 Water supply not constant 20-100 psi.  Instruct customer.
4 Water fill setting too low  (< 6.5 sec’s).  Adjust setting.
5 Too little thermalmastic on thermostat.  Add thermalmastic.
6 Defective thermostat (Open: 48° (9°C) ± 6°, Close: 15°
(-9°C) ± 3°.  Replace icemaker if defective.
T
oo much Ice
1 Shut off arm/linkage bent/broken. Repair or replace
arm/linkage. 
2 If ejector blades rotate with arm in up/OFF position -