44
-
Step Model EX35 Model EX40 Engine Speed Time
Step 1 No Load 2500 r.p.m. 10 min.
Step 2 No Load 3000 r.p.m. 10 min.
Step 3 No Load 3600 r.p.m. 10 min.
Step 4 4.3 HP 4.8 HP 3600 r.p.m. 30 min.
Step 5 8.5 HP 9.5 HP 3600 r.p.m. 30 min.
(33) BREAK-IN OPERATION
A new engine or an engine that has been completely overhauled by being fitted with a new piston,
rings, valves and connecting rod should be thoroughly RUN-IN before being put back into service.
Good bearing surfaces and running clearances between the various parts can only be established by
operating the engine under reduced speed and loads for a short period of time.
While the engine is being tested, check for oil leaks.
Make final carburetor adjustment and regulate the engine operating speed.