5.
The motor is permanently lubricated and requires no oiling.
6. Keep the furnace area clear of any combustible materials, gasoline or other
flammable vapor and liquids.
7.
Before operating furnace, check the location of the furnace vent to make sure
it will not be blocked by the opening of any door on the trailer. If it can be
blocked, do not operate the furnace with the door open.
8. Do not restrict the flow of combustion air or the warm air circulation to the
furnace. To do so could cause personal injury
andlor death.
9. Never operate the furnace if you smell gas. Do not assume that the smell of
gas in your RV is normal. Any time you detect the odor of gas, it is to be
considered life threatening and corrected immediately. Extinguish any open
flames including cigarettes and evacuate all persons from the vehicle. Shut off
gas supply at LP gas bottle. (See safety notice on front cover of this manual.)
10.
lmmediately shut furnace down and call a service agency if furnace cycles
erraticallv or delavs on ianition.
-
WARNlNGl Should overheating occur, or the gas supply fail to shut off.
shut off the manual gas valve to the appliance before shutting off the
electrical supply.
11. Never attempt to repair damaged parts. Always have them replaced by a
qualified service agency.
12. Never attempt to repair the furnace yourself. Seek the help of a qualified
service person.
13.
Never restrict the ducting installed by your trailer manufacturer. To do so
could cause improper furnace operation.
14. Do not install air boosters in the duct system. Such devices will cause the
furnace to cycle on limit and to have erratic sail switch operation.
15. Clothing or other flammable material should not Se placed on or near the
appliance.
16. Always follow the Operating Instructions. Do not deviate from the stepby-
step procedures.
17.
Do not use this appliance if any part has been submerged under water.
lmmediately call a qualified service technician to inspect the appliance and to
replace any part of the control system and any gas control that has been
submerged under water.
18. When considering add-on rooms. porch or patio, attention must be given to
the venting of your furnace. For your safety. do not terminate fumace vent inside
add-on rooms, screen porch or onto patios. Doing so will result in products of
combustion being vented into the room or occupied areas.
19. In any installation in which the vent of this appliance can be covered due to
the constmction of the RV or some special feature of the RV such as slide out,
pop-up etc. always insure that the appliance cannot be operated by setting the
thermostat to the positive
'OFF position and shutting off all electrical and gas
supply to the appliance. Never operate furnace with vent covered.
Your furnace should be inspected by a qualified service agency yearly
before turning the furnace on. Particular attention should be given to the
following items.
1.
lnspect furnace installation and vent termination to
be
sure fumace is properly
secured in place, that vent terminates to the atmosphere and that vent tubes
overlap properly. (See installation manual supplied with furnace.)
2. lnspect chamber and venting to assure that these components are physically
sound, without holes or excessive corrosion and that the installation
andlor
reinstallation is in accordance with Suburban's Installation Instmctions.
(Reference installation manual supplied with furnace.)
WARNlNGl It is imperative that the products of combustion be properly
vented to atmosphere and that all combustion air supplied to burner be
drawn from outside atmosphere.
3.
Check the base on which furnace is mounted. Be sure it is physically sound,
void of any sagging, deterioration, etc.
4. lnspect furnace, the venting, ducting and the gas piping to furnace for obvious
signs of deterioration. Correct any defects at once.
5. lnspect combustion chamber for restrictions in exhaust or intake. It is
imperative that the flow of intake combustion air and the flow of exhaust gases
being expelled to the outside atmosphere not be obstmcted. Any soot or loose
debris should be blown out using
ampressed air. (See Figure
3.)
6. lnspect all gaskets. If any gaskets show signs of leakage of deterioration.
replace them. Safe operation of the fumace depends on all gaskets being tight.
7.
lnspect return air inlet openings to the fumace. Remove any restrictions to
assure adequate air flow.
OPERATING INSTRUCTIONS
WARNlNGl Do not operate furnace while vehicle is in motion or being towed.
NOTE: During initial firing of this furnace a burn-off of excess paint and oils
remaining from manufacturing process may cause 'smoking for
5
-
10
minutes.
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
A.
This appliance does not have a pilot. It is equipped with an ignition device
which automatically lights the burner. Do not light the burner by hand.
6.
BEFORE OPERATING smell all around the appliance area for gas. Be sure
to smell next to
the floor because some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
Extinguish any open flame.
Evacuate all persons from the vehicle.
Shut off the gas supply at the gas container or source.
Do not touch any electric switch or use any phone or radio in the vehicle.
Do not start the vehicle's engine or electric generator.
Contact the nearest gas supplier or qualified service technician for repairs.
If you cannot reach a gas supplier or qualified service technician, contact
the nearest fire department.
Do not turn on the gas supply until the gas leak(s) has been repaired.
C. Use only your hand to push in or turn the gas control knob. Never use tools.
If the knob will not push in or turn by hand. don't
try
to repair it, call a qualified
service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. lmmediately call
a qualified service technician to inspect the appliance and to replace any part
of the control system and any gas control which has been under water.
OPERATING INSTRUCTlONS
I.
STOP1 Read User's Information Manual supplied with furnace.
2. Turn the manual valve (if so equipped) or the valve at the outside LP tank to
the 'OFF" position. Do not force.
3.
Set thermostat above roorrl temperature to begin blower operation. A slight
delay will occur before the blower comes on. Allow blower to run for
5
minutes
for combustion chamber purge cycle.
4. After
5
minutes, move thermostat lever below room temperature. Blower will
remain on. Wait approximately
2
minutes for blower to go off.
5.
Open manual shut-off valve (if so equipped) or the valve at the outside LP
tank. Correct operating characteristics depend on the valve being positioned
open. Never attempt to operate with a valve partially closed.
NOTE: This furnace is equipped with a valve shut-off switch with switch in
'OFF" position. Gas will not flow to burner nor will the furnace operate.
6. Set thermostat to desired setting. NOTE: Motor will not come on instantly.
Allow approximately
30
seconds for motor operation gas flow and sparks.
7.
Allow
30
seconds for main bumer to light after blowercomes on. This furnace
is equipped with an ignition device which automatically ligts the burner. Do not
try to light the bumer by hand.
8. If burner does not light. repeat Steps 1 through 8.
9. If the appliance will not operate, follow the instructions To Turn Off Gas to
Appliance" and call your service technician or gas supplier. NOTE: If the
furnace should lock-out, the blower will go off in
5
minutes and remain off until
unit is reset by reactivating thermostat.
TO TURN OFF GAS TO APPLIANCE
I.
Set the thermostat to lowest setting, then move lever to "OFF position.
3.
Turn shut-off valve to "OFF". Do not force
2.
Turn off all electric power to the appliance if service is to be performed.