34
?-Yes-< Replace the
sail switch.
Yes No
?
?
-Yes-<
Replace the
limit switch.
?
-No-< Replace the module.
? Yes
?
-No-<
Replace the
module.
? Yes
?
?-No-< Check gas
pressure at the manifold or for
restrictions in the burner orifice.
? Yes No
? ?
Yes
Replace the gas valve.
? No
?
?-No- Check flame
contact to electrode. Flame should
be hard blue.
Yes
NOTE: On some models, sail switch is before limit switch.
TROUBLE SHOOTING GUIDE SUBURBAN RV FURNACE with FAN
CONTROL MODULE BOARDS 12 VDC HEATING SECTION
Check thermostat wire connections, Clean points, secure loose
Thermostat Closes -No-< contact points and the heat -Yes-< connections, replace thermostat if
anticipator. anticipator is shorted.
? No
?
? Check 12vdc at blue wire, check the -Yes-
<
Replace thermostat.
amp draw to thermostat.
Yes No
?
? Check for shorts. -Yes-< Repair or replace connections or parts
Check components amperage. with higher than normal amp draw.
? Yes
Check for 12vdc at furnace -No-< Check on/off switch on furnace
? Yes
?
Check fuse or circuit breaker -No-< Replace fuse/Reset breaker.
? Yes
?
-No-< Check for 12vdc at power terminal on -No-<