EasyManuals Logo

Suburban SFV-30 Service Training Manual

Suburban SFV-30
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
38
NT ELECTRODE GAP SPECIFICATIONS
AND POSITIONING



0.125
+.031
-.000
PARK MODEL ELECTRODE GAP SPECIFICATIONS
AND POSITIONING



FLAME SENSOR
GROUND
ELECTRODE
APPROXIMATELY
1
4
" OR TWICE GAP
BETWEEN GROUND
AND ELECTRODE
1
8
"
1
32
"
+
-
Figure 31
Local Flame Sense
Figure 32
Remote Flame Sense
1. 
2. 
1. 
2. 
3. 