Figure
4
MODELS:
SW6P
SW6PE
SW6PR
SW6PER
SW6D
SW6DE
IV.
M
AKING
GAS
CONNECTIONS
A.
C
onnect
a
3/8"
gas
supply
line
to
the
3/8
flare
fitting
at
gas
valve
located
in
the
control
housing.
NOTE:
It
will
be
necessary
to
remove
the
grommet
from
the
control
housing,
make
the
gas
connection
at
the
valve,
then
reinstall
grommet.
WARNING:
It
is
imperative
that
grommet
and
gas
line
through
grommet
be
caulked
air
tight.
If
not
tightly
sealed,
moisture
and
potential
harmful
flue
products
could
vent
through
opening
and
into
living
area
of
trailer.
(See
Figure
7)
B.
T
u
r
n
on
gas
and
check
for
leaks,
using
a
soap
and
water
solution.
Correct
even
the
slightest
leak
immediately.
WARNING!
Do
not
use
an
open
flame
to
check
for
leaks!
V.
M
A
K
I
N
G
ELECTRICAL
CONNECTIONS
12
VOLTS
D.C.
A.
Applicable
to
following
models:
SW6D,SW6DE,
and
SW6DM.
B.
Refer
to
Figure
2
for
location
of
D
C.
junction
box
on
models
SW6D
and
SW6DE.
Refer
to
Figure
6
for
location
of
D
C.
junction
box
on
model
SW6DM.
C.
The
electrical
connections
must
be
made
in
accordance
with
local
codes
and
regulations.
In
the
absence
of
local
codes
and
regulations,
refer
to
the
latest
edition
of
the
National
Electrical
Code
ANSI/NFPA
No.
70.
In
Canada,
the
electrical
installation
should
conform
with
CSA
standard
CSA
C22.2
No.
148/Z240.6.2
Electrical
Requirements
for
Recreational
Vehicles
and
CSA
C22.1
Canadian
Electrical
Code
Part
1
when
installing
the
unit
in
recreational
vehicles
and
mobile
homes
respectively.
Au
Canada,
I'installation
electrique
doit
satisfaire
a
la
norme
ACNOR
22.2
N
148/Z240.6.2
Exigences
electriques
des
vehicules
de
loisir
ou
a
la
norme
ACNOR
C22.1
Premeire
Partie
du
Code
Electrique
Canadien
selon
que
I'appareil
est
installe
dans
un
vehicule
de
loisir
ou
une
maison
rouiante.
D.
Make
sure
the
water
heater
is
filled
with
water
before
making
the
electrical
connections.
E.
Make
the
12
Volt
D.C.
electrical
connections
following
the
wiring
diagram
illustrated
in
Figure
8.
12
VDC.
ONLY
IFANY
OF
THE
ORIGINAL
WIRE
AS
SUPPLIED
WITH
THE
WATER
HEATER
MUST
BE
REPLACED,
IT
MUST
BE
REPLACED
WITH
18
GA.,
105*
C
WIRE
OR
IT’S
EQUIVALENT.
(+)
MODULE
BD.
DISCONNECT
POWER
SUPPLY
BEFORE
SERVICING
THERMOSTAT
AND
HI-LIMIT
UNDER
ACCESS
COVER.
WIRING
DIAGRAM
12
V
DC._340461
si
un
desffls
electriques
livres
avec
le
chauffe-eau
doit
etre
rernplace,
utiliser
a
cet
effet
un
fit
1ft
GA.
105*C
ou
equivalent.
Figure
8
VI.
M
A
K
I
N
G
ELECTRICAL
CONNECTIONS
120
VOLTS
A.C.
A.
Applicable
to
following
models:
SW6PE,
SW6PER,and
SW6DE
B.
Refer
to
Figure
2
for
location
of
A.C.
junction
box.
C.
The
electrical
connections
must
be
made
in
accordance
with
local
codes
and
regulations.
In
the
absence
of
local
codes
and
regulations,
refer
to
the
latest
edition
of
the
National
Electrical
Code
ANSi/NFPA
No.
70.
In
Canada,
the
electrical
installation
should
conform
with
CSA
standard
CSA
C22.2
No.
148/Z240.6.2
Electrical
requirements
for
Recreational
Vehicles
and
CSA
C22.1
Canadian
Electrical
Code
Part
1
when
installing
the
unit
in
recreational
vehicles
and
mobile
homes
respectively.
Au
Canada,
I'installation
electrique
doit
satisfaire
a
la
norme
ACNOR
22.2
N
148/Z240.6.2.
Exigences
electriques
des
vehicules
de
loisir
ou
a
la
norme
ACNOR
C22.1
Premiere
partie
du
Code
electrique
Canadien
selon
que
I'appareil
est
installe
dans
un
vehicule
deloisir
ou
une
maison
rouiante.
Figure
7