INSTRUCTION FOR USE ADVANCED AND WIRELESS
Possible to turn ON and OFF through switch placed on the unit.
STARTUP ADVANCED AND WIRELESS UNITS
At the first startup of the ADVANCED and WIRELESS model products, by setting the on-
board switch to "I" the unit will take from 40 to 60 seconds to open the tilting damper and
then it will start autonomously in automatic AUTO mode, namely with "heat recovery
operation" which means that the machines operate, with opened damper, cyclically 70sec
in extraction and 70sec in supply at medium speed and the hygrostat set point at 60%.
In the following startups the unit will start at the operating mode set before shutdown.
The product has three main running modes and other six modes to be selected through
quick buttons.
The three main modes to be selected through MODE button:
- AUTOMATIC mode
- SURVEILLANCE mode
- MANUAL mode
The six additional modes to be selected through quick buttons:
- NIGHT mode
- BOOST mode
- MASTER-SLAVE AIR FLOW mode
- SLAVE-MASTER AIR FLOW mode
- EXTRACTION mode
- INTAKE mode

Other manuals for Südwind Ambientika ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Südwind Ambientika ADVANCED and is the answer not in the manual?

Südwind Ambientika ADVANCED Specifications

General IconGeneral
BrandSüdwind
ModelAmbientika ADVANCED
CategoryFan
LanguageEnglish

Related product manuals