BUTTONS FUNCTION LIST:
WARNING: the remote control get into stand-by mode after being inactive for 60 seconds
when the icon with key appears on display. To unlock press the button (S) on the upper side
of the remote control.
WARNING: If the unit is connected to other units in the same system, only the MASTER unit
will receive commands that will transfer to all the other SLAVE units connected in sequence.
AUDIO-VISUAL SIGNALS
- Command receipt: when the unit properly receives the command will make a “BIP”
sound and the LED will flash white.
- Surveillance mode: when the product is in surveillance mode the red LED blinks every
60sec.
- Humidity alarm: when the unit gets into humidity alarm the red LED will light up fixed.
- Filter Alarm: when the unit gets into filter alarm the red LED will light up fixed.
WARNING: When turning on the unit the first time and when passing from stand-by or switch
OFF to switch ON, the tilting front cover will take 40 seconds to open.
NOTE: The meaning of “heat recovery operation” corresponds to standard operation of the
product i.e. 70 seconds in extraction and 70 seconds in intake reversing the cycle with
open tilting front cover.