Operating Manual access/eco/peak/power/silent Page
21
4
D
EFECTS -
C
AUSES -
S
OLUTIONS
Solution:
Always replace defective heating. Heating which has not been repaired will
normally lead to another dysfunction within a short time.
4.4. Tripped breaker for transformer 230 VAC: F5 resp. F4 for compact-peak
Possible reasons and solution:
Check the load of the transformer and reset the automatic breaker.
4.5. Tripped breaker for socket: Q2 resp. Q3 for compact-peak
Possible reasons and solution:
The grounded socket is secured by a proper fault current automatic cutout
switch with 13A / 0.03A. Check the performance of the connected devices –
maximum charge 2500 W.
Please also make sure that the grounded socket is connected via the neutral of the
supply. The socket is not able to function at mains without a neutral.