2
2
Product specification
Maintenance
Caution
All maintenance must be conducted while the unit is
unplugged.
* There is risk of electric shock and physi-
cal injuries.
Make sure that the unit is unplugged when in storage.
* There is risk of injury and electric shock.
Disassemble, repair and reassemble is not to be at-
tempted by anyone other than an authorized repair-
man/technician.
* Inadequate or poor handling can result in
fire, malfunction and injuries.
Do use electricity within the allowed range:
198V - 244V.
* There is risk of electric shock and short
circuit.
Do not use the unit in other than the stated opera-
tion conditions.
* Since there is risk of electric shock, short
circuit and malfunction, please use the
unit within the suitable range: 25º (50%
humidity) ~ 45º (40% humidity).
Do not use the unit in places with a lot of cutting oil
or mineral oil.
* They can cause the resin made parts of
the unit to deteriorate, which can result in
accidents and injuries.
Lock the caster wheels with the caster stoppers
before starting to operate the unit.
* The unit can start to move unexpectedly
and cause accidents and injuries.
Do not use in places with electrically conductive dust
from Iron, carbon, casting, aluminium etc.
* Electric shock or fire caused by a short
circuit can occur.
If you use the unit in a very dusty environment,
make sure to clean the interior of the unit regularly.
* Electric shock or fire caused by a short
circuit can occur.
Keep away from re.
* The unit can become deformed, causing
short circuit and possibly fire.
Do not put hands or ngers into the exhaust hole.
* There is risk of injury.
Do not use the unit if the cord or plug is damaged,
or if the plug is loose in the socket.
* Electric shock or fire caused by a short
circuit can occur.
If you use an extension cord, make sure to use one
that meets the specied requirements.
* There is risk of the cord overheating and
catching fire.
Do not let the plug get dirty or get exposed to metal
objects while plugged.
* There is risk of electric shock, short cir-
cuit and fire.
Do not put heavy objects onto the electric cord.
* If the cord gets damaged, there is risk of
electric shock and fire.
Do not use the extension cord while its is coiled or
bundled together.
* There is risk of the cord overheating and
catching fire.
* Make sure that the extension cord is ex-
tended before use.
Do not damage, process, nor bend, pull, twist or
bundle the cord excessively .
* If the cord gets damaged, there is risk of
electric shock or fire.
When you unplug the plug, be sure not to pull it by
the cord, but to pull it out holding the plug directly.
* There is risk of electric shock, short cir-
cuit and fire.
Remove the plug from the electric outlet when the
unit is not in use.
* There is risk of burning and other inju-
ries, electric shock, fire caused by short
circuit etc.
Model number SS-22DD-8A SS-22ED-8A
Automatic swivel Yes No
Power supply Single phase 220V / 50Hz
Cooling capacity 2.2kW
Compressor / output Air tight rotary model / 0,69kW output
Air
ow
Power output 200W
Cool air velocity 5,4m
3
/min (Strong) - 5,2m
3
/min (Weak)
Hot air velocity 9,8m
3
/min
Dimensions (mm) W 390 x D 430 x H 808 (Not including hot/cold air ducts)
Operating condition 25ºC (50%) - 45ºC (40%) Power factor 98%
Power consumption 0,80kW Net weight 37kg
Starting current 15,5A Running current 3,7A
Refrigerant HCFC-22 (R22) Refrigerant charge 320g
Power factor 96% Remarks
All values are measured during operation in 35ºC / 60% humidity